Optimal reconstruction filter parameters for multi-headed brain SPECT: Dependence on count activity

HG Liu, JM Harris, CS Inampudi… - Journal of nuclear …, 1995 - Soc Nuclear Med
Objective: Reconstruction parameters must be optimized to approach the improved spatial
resolution that is theoretically possible from modern SPECT imaging devices. One important …

Optimization of Butterworth filter for brain SPECT imaging

S Minoshima, H Maruno, N Yui, T Togawa… - Annals of nuclear …, 1993 - Springer
A method has been described to optimize the cutoff frequency of the Butterworth filter for
brain SPECT imaging. Since a computer simulation study has demonstrated that separation …

Qualitative evaluation of filter function in brain SPECT [Persian]

E Raeisi, H Rajabi, MR Aghamiri… - Iranian Journal of …, 2007 - irjnm.tums.ac.ir
Introduction: Filtering can greatly affect the quality of clinical images. Determining the best
filter and the proper degree of smoothing can help to ensure the most accurate diagnosis …

High-resolution brain SPECT imaging by combination of parallel and tilted detector heads

A Suzuki, W Takeuchi, T Ishitsu, Y Morimoto… - Annals of nuclear …, 2015 - Springer
Objective To improve the spatial resolution of brain single-photon emission computed
tomography (SPECT), we propose a new brain SPECT system in which the detector heads …

Scatter, spatial resolution, and quantitative recovery in high resolution SPECT

Z Szabo, JM Links, C Seki, J Rhine… - Journal of computer …, 1992 - journals.lww.com
The potential use of single photon emission CT (SPECT) for quantification depends on its
physical performance characteristics. We investigated the performance of a high resolution …

[HTML][HTML] Influences of reconstruction and attenuation correction in brain SPECT images obtained by the hybrid SPECT/CT device: evaluation with a 3-dimensional …

M Akamatsu, Y Yamashita, G Akamatsu… - Asia Oceania Journal …, 2014 - ncbi.nlm.nih.gov
Objective (s): The aim of this study was to evaluate the influences of reconstruction and
attenuation correction on the differences in the radioactivity distributions in 123 I brain …

Evaluation of 2 scatter correction methods using a striatal phantom for quantitative brain SPECT

DC Vines, M Ichise, JS Liow, H Toyama… - Journal of nuclear …, 2003 - Soc Nuclear Med
Objective: Scatter correction is an important factor in quantitative SPECT. In this study, we
evaluated 2 methods of scatter correction for brain SPECT. The first is based on thresholding …

Optimization of iterative reconstruction parameters with 3-dimensional resolution recovery, scatter and attenuation correction in 123I-FP-CIT SPECT

N Matsutomo, A Nagaki, F Yamao, M Sasaki - Annals of nuclear medicine, 2015 - Springer
Objective The aim of this study was to determine the optimal reconstruction parameters on
ordered-subset expectation maximization iterative reconstruction with resolution recovery …

SPECT: state-of-the-art scanners and reconstruction strategies

RJ Jaszczak - … and Brain Pathophysiology Studied with Pet and …, 2021 - taylorfrancis.com
Since 1970, many research groups throughout the world have contributed to the
development of single photon emission computed tomography (SPECT) instrumentation and …

Simulating technetium-99m cerebral perfusion studies with a three-dimensional Hoffman brain phantom: collimator and filter selection in SPECT neuroimaging

HJ Kim, JS Karp, PD Mozley, SO Yang… - Annals of nuclear …, 1996 - Springer
The choice of a collimator and the selection of a filter can affect the quality of clinical SPECT
images of the brain. The compromises that 4 different collimators make between spatial …