Dextrose solutions yield radiochemical impurities: the “sweet” scans
E Al-Enizi, N Kazem, A Owunwanne… - Journal of nuclear …, 2003 - Soc Nuclear Med
Objective: If additional chemicals are inadvertently introduced in the preparation of
radiopharmaceutical kits, radiochemical impurities may be formed. We report our experience …
radiopharmaceutical kits, radiochemical impurities may be formed. We report our experience …
Technetium-99m radiopharmaceutical preparation problems: 12 years of experience
JA Ponto - Journal of nuclear medicine technology, 1998 - Soc Nuclear Med
Objective: Chemical reactions involved in preparing 99mTc radiopharmaceuticals
occasionally result in products of substandard purity. A retrospective examination of …
occasionally result in products of substandard purity. A retrospective examination of …
A better method of quality control for 99mTc-tetrofosmin
R Hammes, LA Joas, TE Kirschling… - Journal of nuclear …, 2004 - Soc Nuclear Med
The method of quality control (QC) described on the package insert for 99mTc-tetrofosmin
requires meticulous attention to technique for accurate radiochemical purity results. About …
requires meticulous attention to technique for accurate radiochemical purity results. About …
[CITATION][C] Radiopharmaceutical Quality Assurance—Pilot Study
WC Eckelman, NE Herrara… - Journal of Nuclear …, 1981 - Soc Nuclear Med
College of American Pathologists completed a pilot study to evaluate radiopharmaceutical
quality assurance techniques. Thirty participants receivedfivevialseach, three for …
quality assurance techniques. Thirty participants receivedfivevialseach, three for …
Evaluation of the stability of 99mTc-ECD and stabilized 99mTc-HMPAO stored in syringes
IL Koslowsky, SE Brake, SJ Bitner - Journal of nuclear medicine …, 2001 - Soc Nuclear Med
Objective: To determine and compare the stability of 99mTc-ECD and stabilized 99mTc-
HMPAO when stored in syringes over an 8-h period. Methods: 99mTc-ECD and stabilized …
HMPAO when stored in syringes over an 8-h period. Methods: 99mTc-ECD and stabilized …
Radiochemical quality control of 99mTc-labeled radiopharmaceuticals: Some daily practice guidelines
EKJ Pauwels, RIJ Feitsma - European journal of nuclear medicine, 1977 - Springer
Recognizing the fact that each nuclear medicine facility should be able to perform simple
radio-chemical quality tests on currently used radiopharmaceuticals, this study was …
radio-chemical quality tests on currently used radiopharmaceuticals, this study was …
Effect of 99Tc on the radiochemical purity of 99mTc radiopharmaceuticals
LA Waight, CM Cunnane, LM O'Brien… - Nuclear Medicine …, 2011 - journals.lww.com
Objective The longer the time between elutions of a technetium-99m (99m Tc) generator, the
greater the 99 Tc: 99m Tc ratio in the eluate. Information is limited on how this affects the …
greater the 99 Tc: 99m Tc ratio in the eluate. Information is limited on how this affects the …
Adsorption of technetium-99m tetrofosmin and technetium-99m furifosmin on plastic syringes
R Bartosch, S Granegger, H Sinzinger - European journal of nuclear …, 1998 - Springer
Some groups have reported that adsorption of radiopharmaceuticals on disposable plastic
syringes can reach levels of almost 50%. This high loss of radioactivity stimulated us to carry …
syringes can reach levels of almost 50%. This high loss of radioactivity stimulated us to carry …
Residual syringe activity: Is there a need for concern?
J Roy, M McMahon, D Gilmore - 2010 - Soc Nuclear Med
2111 Objectives The administration of specifically dosed radio pharmaceuticals to patients is
a very important aspect of Nuclear Medicine. The objective of this study was to examine the …
a very important aspect of Nuclear Medicine. The objective of this study was to examine the …
An alternative method for determining the radiochemical purity of 99mTc-tetrofosmin
KC Amin, S Patel, A Doke, GB Saha - Journal of Nuclear Medicine …, 2011 - Soc Nuclear Med
The instant thin-layer chromatographic method of determining the radiochemical purity of
99mTc-tetrofosmin recommended by the manufacturer uses a mixture of acetone and …
99mTc-tetrofosmin recommended by the manufacturer uses a mixture of acetone and …