[CITATION][C] CAUTION URGED IN USING MICROWAVED TECHNETIUM 99M SESTAMIBI

D Pendleton, T Threadgill - Journal of Nuclear Medicine …, 1993 - Soc Nuclear Med
crowaved Technetium-99m Sestamibi Temperature Reduction." In their letter, the authors
suggest that if a unit dose of Cardiolite (Du Pont Pharma, Billerica, MA) is withdrawn from the …

[CITATION][C] MICROWAVE VERSUS RECON-0-STAT™ FOR PREPARATION OF TECHNETIUM-99M-SESTAMIBI: A COMPARISON OF HAND EXPOSURE …

JC Hung - Journal of nuclear medicine technology, 1996 - Soc Nuclear Med
As shown in the study by Porter and Karvelis, the immediate and 24-hr radiochemical purity
(RCP) values of 99mTc-sestamibi prepared by the Recon-o-Stat method were significantly …

Microwave versus Recon-o-Stat™ for Preparation of Technetium-99m-Sestamibi: A Comparison of Hand Exposure, Radiochemical Purity and Image Quality

WC Porter, KC Karvelis - Journal of nuclear medicine technology, 1995 - Soc Nuclear Med
Objective: Multiple methods of preparing 99mTc Cardiolite® are routinely utilized. The most
recent method available is the Recon-o-Stat™ which employs heat-pump technology. The …

[CITATION][C] Breakage of technetium-99m-sestamibi vial with the use of a microwave oven

JC Hung, RJ Gibbons - Journal of nuclear medicine, 1992 - Soc Nuclear Med
side wall and the base, while the vial top including the metal cap and rubber stopper
remained intact. Previous experiments indicate that excessive pressure may build up inside …

[CITATION][C] Microwave preparation of and one-strip paper chromatography for technetium Tc 99m teboroxime

ME Wilson, JC Hung - American Journal of Hospital Pharmacy, 1993 - academic.oup.com
Technetium Tc 99m teboroxime is used as a myo cardial perfusion imaging agent for
distinguish ing normal from abnormal myocardium in pa tients with suspected coronary …

[CITATION][C] Ultrasonic visualization of tablets in the gastrointestinal tract

JC Maublant, H Hassine, M Sournac… - Journal of Nuclear …, 1988 - Soc Nuclear Med
TO THE EDITOR: In addition to our work on the in vivo measurement of the dissolution rates
and gastrointestinal transit times of technetium-99m-(99mTc) labeled tablets (/), we would …

[PDF][PDF] Problems with fractionated cold kits

C Decristoforo, G Riccabona - Journal of Nuclear Medicine, 1996 - Soc Nuclear Med
TO THE EDITOR: Cost-effective preparationof" Te radiopharma-ceuticals by fractionated use
of expensive cold kits has been explored extensively in recent years and has been …

99Technetiumm DTPA does not break down during ultrasound nebulization

S Groth, H Funch‐Rosenberg, J Mortensen… - Clinical …, 1989 - Wiley Online Library
For several years aerosolized 99Tcm‐DTPA has been used for studies of pulmonary
permeability. Comparable results have been obtained regardless of the 99Tcm‐DTPA …

[PDF][PDF] Rapid preparation and quality control method for technetium-99m-2-methoxy isobutyl isonitrile (technetium-99m-sestamibi)

JC Hung, ME Wilson, ML Brown… - Journal of Nuclear …, 1991 - Soc Nuclear Med
Rapid Preparation and Quality Control Method for Technetium-9 9m—2-MethoxyIsobutyl
Isonitrile (Technetium.-99m-Sestamibi) Page 1 pharmaceutical during coronary occlusion (2—7).Tech …

An alternative method for rapid preparation of 99Tcm-sestamibi

ME Wilson, JC Hung, RJ Gibbons - Nuclear medicine …, 1993 - journals.lww.com
The availability of 99Tcm-sestamibi is limited, especially in emergency cases due to the time-
consuming preparation procedure that requires a 10-min boiling water bath and a 30-min …