Estimation of fan beam and parallel beam parameters in a wire mesh design

A Khorshidi, M Ashoor, SH Hosseini… - Journal of Nuclear …, 2012 - Soc Nuclear Med
Special collimators used in imaging systems play an important part in obtaining qualified
images to improve diagnosis in medicine. Methods: The primary aim of this study was to …

Evaluation of collimators' response: Round and hexagonal holes in parallel and fan beam

A Khorshidi, M Ashoor, SH Hosseini… - Progress in Biophysics and …, 2012 - Elsevier
With regard to the different requirements, various collimators are widely employed within
nuclear medicine systems in order to evaluate the metabolism of organs as well as improve …

Characterisation of fan-beam collimators

D Pareto, J Pavía, C Falcón, I Juvells, A Cot… - European journal of …, 2001 - Springer
Fan-beam collimators offer a good balance between resolution and noise. The collimator
response may be included in iterative reconstruction algorithms in order to improve single …

The evaluation and calibration of fan-beam collimators

JL Mahowald, PD Robins, MK O'Connor - European journal of nuclear …, 1999 - Springer
The aims of this study were (a) to determine the true focal length of a fan-beam collimator
and (b) to calibrate image size (mm/pixel) for each collimator to permit inter-comparison of …

Modulation transfer function assessment in parallel beam and fan beam collimators with square and cylindrical holes

A Khorshidi, M Ashoor - Annals of Nuclear Medicine, 2014 - Springer
Objective This study investigates modulation transfer function (MTF) in parallel beam (PB)
and fan beam (FB) collimators using the Monte Carlo method with full width at half maximum …

Evaluation of the geometric, scatter, and septal penetration components in fan-beam collimators using Monte Carlo simulation

A Cot, J Sempau, D Pareto, S Bullich… - … on Nuclear Science, 2002 - ieeexplore.ieee.org
The quantitative analysis of single-photon emission computed tomography data requires an
accurate determination of the collimator point spread function (PSF). The aim of this paper is …

[PDF][PDF] Half-fanbeam collimators combined with scanning point sources for simultaneous emission-transmission imaging

FJ Beekman, C Kamphuis, BF Hutton… - Journal of Nuclear …, 1998 - Soc Nuclear Med
One type of SPECT system often used for simultaneous emissiontransmission tomography
isequipped with parallel-hole collimators, moving line sources (MLS) and electronic …

Geometrical response modeling in fan-beam collimators-A numerical simulation

D Pareto, A Cot, C Falcon, I Juvells… - IEEE Transactions on …, 2002 - ieeexplore.ieee.org
Iterative reconstruction algorithms require modeling of the point spread function (PSF) of the
collimator in order to correct the loss of resolution in single photon emission computed …

Design and performance evaluation of a new high energy parallel hole collimator for radioiodine planar imaging by gamma cameras: Monte Carlo simulation study

V Moslemi, M Ashoor - Annals of nuclear medicine, 2017 - Springer
Objective In addition to the trade-off between resolution and sensitivity which is a common
problem among all types of parallel hole collimators (PCs), obtained images by high energy …

Performance study of a fan beam collimator designed for a multi-modality small animal imaging device

ASMS Ahmed, GH Kramer, W Semmler… - Nuclear Instruments and …, 2011 - Elsevier
This paper describes the methodology to design and conduct the performances of a fan
beam collimator. This fan beam collimator was designed to use with a multi-modality small …