[HTML][HTML] Radiolysis-Associated Decrease in Radiochemical Purity of 177Lu-Radiopharmaceuticals and Comparison of the Effectiveness of Selected Quenchers …
A Larenkov, I Mitrofanov, E Pavlenko, M Rakhimov - Molecules, 2023 - mdpi.com
The radiolytic degradation of vector molecules is a major factor affecting the shelf life of
therapeutic radiopharmaceuticals. The development of time-stable dosage forms of …
therapeutic radiopharmaceuticals. The development of time-stable dosage forms of …
Pitfalls and limitations of SPECT, PET, and therapeutic radiopharmaceuticals
JR Ballinger - Seminars in nuclear medicine, 2015 - Elsevier
Radiopharmaceuticals are widely accepted to be a very safe class of drugs, with very few
adverse reactions and unexpected biodistributions. However, problems can arise because …
adverse reactions and unexpected biodistributions. However, problems can arise because …
Comparison of FASTlab 18F-FDG production using phosphate and citrate buffer cassettes
JZ Long, MS Jacobson, JC Hung - Journal of Nuclear Medicine …, 2013 - Soc Nuclear Med
The objective of this research is to determine whether there are significant differences in the
18F-FDG produced by either the phosphate or the citrate buffer cassettes in the FASTlab …
18F-FDG produced by either the phosphate or the citrate buffer cassettes in the FASTlab …
Upgrades and regulatory aspects of [18F]Fluorodeoxyglucose ([18F]FDG) production using the FASTLab2 synthesizer
MFA Fadzil, Z Ashhar, ZM Safee - Journal of Radioanalytical and Nuclear …, 2022 - Springer
The production of [18 F] Fluorodeoxyglucose ([18 F] FDG) using a GE FASTLab2 synthesizer
enables to obtain higher radiochemical yields including more robust synthesis process. This …
enables to obtain higher radiochemical yields including more robust synthesis process. This …
Autoradiolytic Decomposition of Radiopharmaceutical 2-[18F]Fluorodeoxyglucose
SD Brinkevich, OV Tugai, DI Nevzorov - High Energy Chemistry, 2019 - Springer
The kinetics of autoradiolytic degradation of the radiopharmaceutical drug 2-[18 F]
fluorodeoxyglucose ([18 F] FDG) in an air-saturated normal saline solution with initial activity …
fluorodeoxyglucose ([18 F] FDG) in an air-saturated normal saline solution with initial activity …
A two‐center study for the quality control of [18F]FDG using FASTlab phosphate cassettes
Abstract Objective The GE FASTlab radiosynthesis module is routinely used for the
production of [18 F] FDG, utilizing the commercially available phosphate cassettes. Because …
production of [18 F] FDG, utilizing the commercially available phosphate cassettes. Because …
[PDF][PDF] Changes in the radiochemical purity of [18F] FDG radiopharmaceutical according to the amount of ethanol added
S Kim, E Han - International Journal of Radiation Research, 2020 - sid.ir
Background: we aimed to find the optimal level of ethanol that can be added such that the
radiochemical purity of [18F] FDG is increased and the MFDS and USP stipulated guidelines …
radiochemical purity of [18F] FDG is increased and the MFDS and USP stipulated guidelines …
An optimized radiosynthesis of [18F]DK222, a PET radiotracer for imaging PD‐L1
A radiochemical synthesis of [18F] DK222, a peptide binder of programmed death ligand 1
protein, suitable for human PET studies is described, and results from validation productions …
protein, suitable for human PET studies is described, and results from validation productions …
Radiation-Induced Transformations of 2-Fluoroethanol in Aqueous Solutions
SD Brinkevich, OV Tuhai, AA Sladkova… - High Energy …, 2020 - Springer
Steady-state radiolysis has been used to study the radiation-induced transformations of 2-
fluoroethanol in dilute aqueous solutions as a model system for examining the autoradiolytic …
fluoroethanol in dilute aqueous solutions as a model system for examining the autoradiolytic …
Optimization of precursor synthesis, formulation and stability of 1′-[18 F] fluoroethyl-β-D-lactose ([18 F] FEL) for preclinical studies in detection of pancreatic cancer
V Paolillo, L De Palatis, MM Alauddin - Nuclear medicine and biology, 2014 - Elsevier
Abstract Introduction 1′-[18 F] Fluoroethyl-β-d-lactose ([18 F] FEL) is a new PET imaging
agent for early detection of pancreatic cancer and hepatocellular carcinoma. We previously …
agent for early detection of pancreatic cancer and hepatocellular carcinoma. We previously …