[HTML][HTML] Automated data quality control in FDOPA brain PET imaging using deep learning

AD Pontoriero, G Nordio, R Easmin, A Giacomel… - Computer Methods and …, 2021 - Elsevier
Introduction. With biomedical imaging research increasingly using large datasets, it
becomes critical to find operator-free methods to quality control the data collected and the …

Performance characteristics of PET scanners

GB Saha, GB Saha - Basics of PET imaging: physics, chemistry, and …, 2010 - Springer
A major goal of the PET studies is to obtain a good quality and detailed image of an object
by the PET scanner, and so it depends on how well the scanner performs in image …

Performance evaluation of PET scanners: testing of geometric arc correction by off-centre uniformity measurement

R Buchert, KH Bohuslavizki, H Fricke, J Mester… - European journal of …, 2000 - Springer
The aim of this study was to demonstrate the necessity of an off-centre uniformity
measurement during performance evaluation and acceptance testing of a positron emission …

[HTML][HTML] Importance of understanding and analyzing daily quality assurance test of positron emission tomography/computed tomography equipment in minimizing the …

S Tayal, A Ali, V Kumar, AK Jha… - Indian Journal of Nuclear …, 2021 - journals.lww.com
This article briefly describes the event of a defective detector block in a daily quality
assurance scan/blank scan and insists on implementing guidelines to scan or not to scan in …

Positron Emission Tomography

GB Saha, GB Saha - Physics and Radiobiology of Nuclear Medicine, 2013 - Springer
Positron emission tomography (PET) is based on the detection in coincidence of the two 511-
keV annihilation radiations that originate from β+-emitting sources, such as the patient …

[PDF][PDF] Controle de qualidade de imagem em tomografia por emissão de pósitrons

LV de Sá - 2010 - nuclear.ufrj.br
Medicina Nuclear (MN) é uma especialidade médica na qual um composto químico
contendo um isótopo radioativo é administrado a um paciente por via oral, intravenosa ou …

Occurrence of an artifact in brain 18F-FDG PET with calculated attenuation correction

D von Borczyskowski, U Schulte… - Journal of nuclear …, 2006 - Soc Nuclear Med
In infants, brain 18F-FDG PET often requires sedation. To keep the sedation mild, the PET
acquisition time should be kept short. Therefore, calculated attenuation correction is often …

[BOOK][B] Synthesis and quality control of fluorodeoxyglucose and performance assessment of Siemens MicroFocus 220 small animal PET scanner

SN Phaterpekar - 2016 - search.proquest.com
The scope of this article is to cover the synthesis and quality control procedures involved in
production of Fludeoxyglucose (18 F–FDG). The article also describes the cyclotron …

Performance Characteristics of PET Scanners

GB Saha, PhD, GB Saha - Basics of PET Imaging: Physics, Chemistry, and …, 2016 - Springer
Several parameters associated with PET scanners are critical to good-quality image
formation, which include spatial resolution, sensitivity, noise, scattered radiations, and …

Significant Head Motion Can Cause Either Hypermetabolic or Hypometabolic Cerebral Activity on 18F-FDG PET/CT

LT Ho, V Ngo, H Vuu, R Montion - Clinical Nuclear Medicine, 2012 - journals.lww.com
We report 2 separate cases with significant head motion causing apparent hypometabolic
and hypermetabolic cerebral activity on FDG PET/CT. Case 1 is a 57-year-old man with …