FDG manual injection verses infusion system: a comparison of dose precision and extravasation
S Krumrey, R Frye, I Tran, P Yost, N Nguyen, M Osman - 2009 - Soc Nuclear Med
2031 Objectives The MEDRAD Intego™ PET Infusion System (Intego) is designed to deliver
a more patient-specific FDG dose. We evaluated the precision of the FDG dose delivery and …
a more patient-specific FDG dose. We evaluated the precision of the FDG dose delivery and …
Effect of PET scan with count reduction using AI-based processing techniques on image quality
3095 Objectives: Subtle Medical created the first Artificial Intelligent (AI) processing for F18-FDG
(FDG) PET/CT imaging which was FDA approved in 2018. Subtle Medical specialized …
(FDG) PET/CT imaging which was FDA approved in 2018. Subtle Medical specialized …
A photopenic circular artifact that resulted in a gamma camera head rebuild: A technologist case study
792 Objectives: A photopenic circular artifact and increasing integral uniformity values on
daily quality control on a gamma camera detector caused our department to call in the field …
daily quality control on a gamma camera detector caused our department to call in the field …
The Need for Increased Awareness About Potential Quality Control Problems in Aging γ-Cameras
S Frye, R Frye, B Sterkel, R Muzaffar… - Journal of Nuclear …, 2019 - Soc Nuclear Med
Quality control in a nuclear medicine department plays an important role in providing quality
care for patients. Closely monitoring the uniformity values on extrinsic quality control can …
care for patients. Closely monitoring the uniformity values on extrinsic quality control can …
Analysis of spill kit procedures in local healthcare systems
TS26 Introduction: 10 CFR 20.1101 states that Nuclear Regulatory Commisson (NRC) licensees
implement a radiation protection program including information on radioactivity spills (1)…
implement a radiation protection program including information on radioactivity spills (1)…
The Effects of MRI on RF-Based Contactless Smart Cards
A Bulla, S Frye, R Frye - 2021 - Soc Nuclear Med
3009 Objectives: Multiple MRI employees reported faulty radiofrequency-based contactless
smart cards after leaving Zone 4 in the MRI department. This experiment was conducted to …
smart cards after leaving Zone 4 in the MRI department. This experiment was conducted to …
Increasing awareness of a quality control problem in aging gamma cameras
SA Frye, RJ Frye, B Sterkel, R Muzaffar… - Journal of Nuclear …, 2019 - Soc Nuclear Med
Quality control (QC) in a nuclear medicine department plays an important role in providing
quality care for patients. Closely monitoring the uniformity values on extrinsic QC can give …
quality care for patients. Closely monitoring the uniformity values on extrinsic QC can give …
Returning to work after I-131 treatment: A Nuclear Medicine Technologist's Personal Experience
2016 Objectives: Radiation safety guidelines for the release of patients receiving radioactive
iodine (RAI) treatment are well established. However, these guidelines are rarely tailored to …
iodine (RAI) treatment are well established. However, these guidelines are rarely tailored to …
A Visual Demonstration of Crystal Scintillation
R Frye, S Frye, R Warhoover, E Hooper - 2020 - Soc Nuclear Med
3002 Objectives: The purpose of this study is to give a practical demonstration and explanation
of a NaI crystal scintillation in a nuclear medicine department. In pursuit of this goal, the …
of a NaI crystal scintillation in a nuclear medicine department. In pursuit of this goal, the …
Digital vs Analog: PET/CT Spatial Resolution
2064 Objectives: The objective of this study is to determine and compare the spatial resolution
of digital and analog PET/CT systems by constructing a National Electrical Manufacturers …
of digital and analog PET/CT systems by constructing a National Electrical Manufacturers …