Dosimetry for radiopharmaceutical therapy: current practices and commercial resources
…, SS James, P Zanzonico, BE Zimmerman - Journal of Nuclear …, 2021 - Soc Nuclear Med
With the ongoing dramatic growth of radiopharmaceutical therapy, research and development
in internal radiation dosimetry continue to advance both at academic medical centers and …
in internal radiation dosimetry continue to advance both at academic medical centers and …
Experimental determinations of commercial 'dose calibrator'settings for nuclides used in nuclear medicine
BE Zimmerman, JT Cessna - Applied Radiation and Isotopes, 2000 - Elsevier
Commercial reentrant ionization chambers (‘dose calibrators’) have become the de facto
standard instrument for making radioactivity measurements in the radiopharmaceutical industry…
standard instrument for making radioactivity measurements in the radiopharmaceutical industry…
[HTML][HTML] Multi-centre evaluation of accuracy and reproducibility of planar and SPECT image quantification: an IAEA phantom study
BE Zimmerman, D Grošev, I Buvat, MAC Pérez… - … für Medizinische Physik, 2017 - Elsevier
… Author links open overlay panel Brian E. Zimmerman 1 , Darko Grošev 2 , Irène Buvat 3 ,
Marco A. Coca Pérez 4 , Eric C. Frey 5 , Alan Green 6 , Anchali Krisanachinda 7 , Michael …
Marco A. Coca Pérez 4 , Eric C. Frey 5 , Alan Green 6 , Anchali Krisanachinda 7 , Michael …
Development of a traceable calibration methodology for solid 68Ge/68Ga sources used as a calibration surrogate for 18F in radionuclide activity calibrators
BE Zimmerman, JT Cessna - Journal of Nuclear Medicine, 2010 - Soc Nuclear Med
We have developed a methodology for calibrating 68 Ge radioactivity content in a
commercially available calibration source for activity calibrators in a way that is traceable to the …
commercially available calibration source for activity calibrators in a way that is traceable to the …
Automated cassette-based production of high specific activity [203/212Pb] peptide-based theranostic radiopharmaceuticals for image-guided radionuclide therapy for …
…, D Lee, D Liu, F Kunkel, BE Zimmerman… - Applied radiation and …, 2017 - Elsevier
A method for preparation of Pb-212 and Pb-203 labeled chelator-modified peptide-based
radiopharmaceuticals for cancer imaging and radionuclide therapy has been developed and …
radiopharmaceuticals for cancer imaging and radionuclide therapy has been developed and …
203/212Pb theranostic radiopharmaceuticals for image-guided radionuclide therapy for cancer
…, S Mirzadeh, BE Zimmerman… - Current medicinal …, 2020 - ingentaconnect.com
Receptor-targeted image-guided Radionuclide Therapy (TRT) is increasingly recognized as
a promising approach to cancer treatment. In particular, the potential for clinical translation …
a promising approach to cancer treatment. In particular, the potential for clinical translation …
Construction and implementation of the NIST triple-to-double coincidence ratio (TDCR) spectrometer
BE Zimmerman, R Collé, JT Cessna - Applied radiation and isotopes, 2004 - Elsevier
A description of the triple-to-double coincidence ratio (TDCR) spectrometer recently
constructed at NIST and results of tests to assess its operating characteristics are presented. …
constructed at NIST and results of tests to assess its operating characteristics are presented. …
Traceability in nuclear medicine
BE Zimmerman, S Judge - Metrologia, 2007 - iopscience.iop.org
Accurate, reproducible measurement of radioactivity in nuclear medicine applications is vital
to ensure the safety and effectiveness of disease diagnosis and treatment using unsealed …
to ensure the safety and effectiveness of disease diagnosis and treatment using unsealed …
Overcoming barriers to radiopharmaceutical therapy (RPT): an overview from the NRG-NCI working group on dosimetry of radiopharmaceutical therapy
Radiopharmaceutical therapy (RPT) continues to demonstrate tremendous potential in
improving the therapeutic gains in radiation therapy by specifically delivering radiation to tumors …
improving the therapeutic gains in radiation therapy by specifically delivering radiation to tumors …
[HTML][HTML] Standardization of 68Ge/68Ga using three liquid scintillation counting based methods
BE Zimmerman, JT Cessna… - Journal of Research of the …, 2008 - ncbi.nlm.nih.gov
A solution containing 68 Ge in equilibrium with its daughter, 68 Ga, has been standardized
for the first time at the National Institute of Standards and Technology (NIST) using 3 liquid …
for the first time at the National Institute of Standards and Technology (NIST) using 3 liquid …