Dosimetry for radiopharmaceutical therapy: current practices and commercial resources

…, SS James, P Zanzonico, BE Zimmerman - Journal of Nuclear …, 2021 - Soc Nuclear Med
With the ongoing dramatic growth of radiopharmaceutical therapy, research and development
in internal radiation dosimetry continue to advance both at academic medical centers and …

Experimental determinations of commercial 'dose calibrator'settings for nuclides used in nuclear medicine

BE Zimmerman, JT Cessna - Applied Radiation and Isotopes, 2000 - Elsevier
Commercial reentrant ionization chambers (‘dose calibrators’) have become the de facto
standard instrument for making radioactivity measurements in the radiopharmaceutical industry…

[HTML][HTML] Multi-centre evaluation of accuracy and reproducibility of planar and SPECT image quantification: an IAEA phantom study

BE Zimmerman, D Grošev, I Buvat, MAC Pérez… - … für Medizinische Physik, 2017 - Elsevier
… Author links open overlay panel Brian E. Zimmerman 1 , Darko Grošev 2 , Irène Buvat 3 ,
Marco A. Coca Pérez 4 , Eric C. Frey 5 , Alan Green 6 , Anchali Krisanachinda 7 , Michael …

Development of a traceable calibration methodology for solid 68Ge/68Ga sources used as a calibration surrogate for 18F in radionuclide activity calibrators

BE Zimmerman, JT Cessna - Journal of Nuclear Medicine, 2010 - Soc Nuclear Med
We have developed a methodology for calibrating 68 Ge radioactivity content in a
commercially available calibration source for activity calibrators in a way that is traceable to the …

Automated cassette-based production of high specific activity [203/212Pb] peptide-based theranostic radiopharmaceuticals for image-guided radionuclide therapy for …

…, D Lee, D Liu, F Kunkel, BE Zimmerman… - Applied radiation and …, 2017 - Elsevier
A method for preparation of Pb-212 and Pb-203 labeled chelator-modified peptide-based
radiopharmaceuticals for cancer imaging and radionuclide therapy has been developed and …

203/212Pb theranostic radiopharmaceuticals for image-guided radionuclide therapy for cancer

…, S Mirzadeh, BE Zimmerman… - Current medicinal …, 2020 - ingentaconnect.com
Receptor-targeted image-guided Radionuclide Therapy (TRT) is increasingly recognized as
a promising approach to cancer treatment. In particular, the potential for clinical translation …

Construction and implementation of the NIST triple-to-double coincidence ratio (TDCR) spectrometer

BE Zimmerman, R Collé, JT Cessna - Applied radiation and isotopes, 2004 - Elsevier
A description of the triple-to-double coincidence ratio (TDCR) spectrometer recently
constructed at NIST and results of tests to assess its operating characteristics are presented. …

Traceability in nuclear medicine

BE Zimmerman, S Judge - Metrologia, 2007 - iopscience.iop.org
Accurate, reproducible measurement of radioactivity in nuclear medicine applications is vital
to ensure the safety and effectiveness of disease diagnosis and treatment using unsealed …

Overcoming barriers to radiopharmaceutical therapy (RPT): an overview from the NRG-NCI working group on dosimetry of radiopharmaceutical therapy

…, Y Seo, EC Frey, WE Bolch, BE Zimmerman… - International Journal of …, 2021 - Elsevier
Radiopharmaceutical therapy (RPT) continues to demonstrate tremendous potential in
improving the therapeutic gains in radiation therapy by specifically delivering radiation to tumors …

[HTML][HTML] Standardization of 68Ge/68Ga using three liquid scintillation counting based methods

BE Zimmerman, JT Cessna… - Journal of Research of the …, 2008 - ncbi.nlm.nih.gov
A solution containing 68 Ge in equilibrium with its daughter, 68 Ga, has been standardized
for the first time at the National Institute of Standards and Technology (NIST) using 3 liquid …