Evaluation of zeta-potential and particle size of technetium 99mTc-sulfur colloid subsequent to the addition of lidocaine and sodium bicarbonate

J Nucl Med Technol. 2010 Mar;38(1):49-52. doi: 10.2967/jnmt.109.068973. Epub 2010 Feb 16.

Abstract

The use of (99m)Tc-sulfur colloid lymphoscintigraphy for the determination of lymph flow patterns from a tumor site and localization of the sentinel node has been widely adopted. However, the effects of multiple injections of the radiopharmaceutical can range from mild discomfort to pain. pH-adjusted lidocaine HCl coadministered with (99m)Tc-sulfur colloid presents a risk of introducing instability of the radiopharmaceutical, which could lead to aggregation, possibly impeding the kinetics of lymphatic drainage from the tumor site.

Methods: In the present study, lidocaine pH-adjusted with 4.2%, 6.3%, or 8.4% sodium bicarbonate was added to the (99m)Tc-sulfur colloid radiopharmaceutical to monitor effects on radiochemical purity, zeta-potential, particle size, and pH. These parameters were then used to evaluate the short-term stability of the preparation.

Results: The study revealed that the formulation of lidocaine pH-adjusted with 8.4% sodium bicarbonate added to (99m)Tc-sulfur colloid demonstrated a similar change in zeta-potential (-4.09 +/- 2.90 mV) and particle size (10-330 nm) to that of control filtered (99m)Tc-sulfur colloid (-5.09 +/- 1.68 mV and 11-343 nm, respectively). However, the 4.2% preparation showed a zeta-potential of -3.01 +/- 2.24 mV and a particle size range of 10-351 nm. The pH of the 8.4% buffered preparation, at 7.1, was closer to physiologic pH than was the control, at 6.0. The 6.3% pH-adjusted lidocaine-(99m)Tc-sulfur colloid preparation failed radiochemical purity; thus, it was not included in the analysis.

Conclusion: Compared with other (99m)Tc-sulfur colloid test formulations of 4.2% and 6.3% pH-adjusted lidocaine, the 8.4% sodium bicarbonate pH-adjusted lidocaine-(99m)Tc-sulfur colloid preparation, taken as a whole, yielded superior quality-control parameters. This formulation would be an acceptable alternative to the control.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Humans
  • Hydrogen-Ion Concentration
  • Lidocaine / chemistry*
  • Particle Size*
  • Sodium Bicarbonate / chemistry*
  • Technetium Tc 99m Sulfur Colloid / chemistry*

Substances

  • Technetium Tc 99m Sulfur Colloid
  • Sodium Bicarbonate