Parathyroid imaging: the importance of dual-radiopharmaceutical simultaneous acquisition with 99mTc-sestamibi and 123I

J Nucl Med Technol. 2012 Jun;40(2):104-10. doi: 10.2967/jnmt.111.098400. Epub 2012 May 7.

Abstract

Our objective was to compare the accuracy of 3 imaging protocols for the detection of parathyroid adenomas: single-tracer, dual-phase imaging with (99m)Tc-sestamibi; dual-tracer, single-phase imaging with simultaneous acquisition of (99m)Tc-sestamibi and (123)I images; and dual-tracer, dual-phase imaging with simultaneous acquisition of (99m)Tc-sestamibi and (123)I images.

Materials: Thirty-seven patients with surgical proof of parathyroid adenomas were evaluated. Three different protocols were derived from a single study in each patient, resulting in an intrapatient intrastudy comparison. The first derived protocol was the conventional dual-phase protocol with (99m)Tc-sestamibi consisting of anterior and anterior-oblique pinhole images of the neck at 15 min and 3 h plus parallel-hole images of the neck and upper chest at both imaging times. The second derived protocol was a dual-tracer, single-phase protocol consisting of administration of (123)I followed 2 h later by (99m)Tc-sestamibi. Fifteen minutes later, anterior and anterior oblique pinhole images of the (99m)Tc-sestamibi and (123)I were acquired simultaneously, allowing generation of perfectly coregistered subtraction images. Parallel-hole images of the neck and upper chest were also obtained. The third protocol was the same as the second except that the same imaging protocol was repeated at 3 h. Two experienced nuclear medicine physicians indicated the location of any identified lesion and graded the certainty of diagnosis on a 3-point scale.

Results: Thirty-seven patients had 41 parathyroid adenomas. For the 2 observers combined, the localization success rate was 66% for the single-tracer, dual-phase protocol; 94% for the dual-tracer, single-phase protocol; and 90% for the dual-phase, dual-tracer protocol. Both dual-tracer protocols were significantly more accurate than the single-tracer protocol (P < 0.01); there was no significant difference between the 2 dual-tracer protocols. In addition, the degree of certainty of localization was greater with the 2 dual-tracer protocols than the single-tracer protocol (P < 0.001).

Conclusion: A dual-tracer, single-phase parathyroid imaging protocol consisting of simultaneous acquisition of (99m)Tc-sestamibi and (123)I images with pinhole collimation at 15 min and perfectly coregistered subtraction results in a higher degree of accuracy and a greater degree of diagnostic certainty than the commonly used single-tracer, dual-phase protocol of imaging (99m)Tc-sestamibi alone at 15 min and 3 h. The addition of delayed imaging to the dual-tracer protocol did not improve results.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adult
  • Aged
  • Aged, 80 and over
  • Female
  • Humans
  • Image Interpretation, Computer-Assisted
  • Iodine Radioisotopes
  • Male
  • Middle Aged
  • Parathyroid Glands / diagnostic imaging*
  • Parathyroid Glands / pathology
  • Parathyroid Glands / surgery
  • Radionuclide Imaging / methods*
  • Radiopharmaceuticals*
  • Technetium Tc 99m Sestamibi*
  • Time Factors

Substances

  • Iodine Radioisotopes
  • Radiopharmaceuticals
  • Technetium Tc 99m Sestamibi