Comparison of six quantitative methods for the measurement of bone turnover at the hip and lumbar spine using 18F-fluoride PET-CT

Nucl Med Commun. 2012 Jun;33(6):597-606. doi: 10.1097/MNM.0b013e3283512adb.

Abstract

Aim: The aim of this study was to evaluate the relationship between different quantification methods used for the measurement of bone plasma clearance (K(i)) using F-PET at the hip and lumbar spine.

Methods: Twelve healthy postmenopausal women aged 52-71 years were recruited. Each participant underwent 60-min dynamic F-PET scans at the lumbar spine and hip on two separate occasions with an injected activity of 90 and 180 MBq, respectively. Image-derived input functions were obtained at the aorta from the lumbar spine scans. K(i) was evaluated using a three-compartment four-parameter model (K(i-4k)), three-compartment three-parameter model (K(i-3k)), Patlak analysis (K(i-Pat)), spectral analysis (K(i-Spec)) and deconvolution (K(i-Decon)). Standardized uptake values (SUVs) were also measured.

Results: The Pearson correlation between K(i-4k) and K(i-3k), K(i-Pat), K(i-Spec), K(i-Decon) and SUV were 0.91, 0.97, 0.94, 0.95 and 0.93, respectively, with a significance of P less than 0.0001. The differences between the correlations measured using Fisher's Z-test were not significant (P>0.05). Bland-Altman analysis showed that the limits of agreement for K(i) measured as the SD of the differences were 0.0082 (25.9%), 0.0062 (11.7%), 0.0098 (20.1%) and 0.0056 (25.5%) ml/min/ml, respectively, and the biases were -0.0081 (-23.8%), -0.0075 (-23.7%), -0.0107 (-29.5%) and -0.0015 (0.8%) ml/min/ml, respectively.

Conclusion: All five methods of quantification (K(i-3k), K(i-Pat), K(i-Spec), K(i-Decon) and SUV) strongly correlated with K(i-4k). Although systematic differences of up to 29% were found between K(i-4k) and the other methods (K(i-3k), K(i-Pat), K(i-Spec) and K(i-Decon)), these should not affect the conclusions of clinical studies, provided the methods are applied consistently. However, care should be taken when comparing reports that use different methods of quantification.

Publication types

  • Comparative Study
  • Evaluation Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Aged
  • Algorithms
  • Bone Remodeling / physiology*
  • Female
  • Fluorodeoxyglucose F18
  • Hip Joint / diagnostic imaging*
  • Hip Joint / metabolism
  • Humans
  • Lumbar Vertebrae / diagnostic imaging*
  • Lumbar Vertebrae / metabolism
  • Middle Aged
  • Multimodal Imaging / methods*
  • Positron-Emission Tomography*
  • Radiopharmaceuticals
  • Reproducibility of Results
  • Tomography, X-Ray Computed*

Substances

  • Radiopharmaceuticals
  • Fluorodeoxyglucose F18