18-Fluorodeoxyglucose imaging with positron emission tomography and single photon emission computed tomography: cardiac applications

Semin Nucl Med. 2000 Oct;30(4):281-98. doi: 10.1053/snuc.2000.9543.

Abstract

The assessment of myocardial viability has become an important aspect of the diagnostic and prognostic work-up of patients with ischemic cardiomyopathy. Although revascularization may be considered in patients with extensive viable myocardium, patients with predominantly scar tissue should be treated medically or evaluated for heart transplantation. Among the many viability tests, noninvasive assessment of cardiac glucose use (as a marker of viable tissue) with F18-fluorodeoxyglucose (FDG) is considered the most accurate technique to detect viable myocardium. Cardiac FDG uptake has traditionally been imaged with positron emission tomography (PET). Clinical studies have shown that FDG-PET can accurately identify patients with viable myocardium that are likely to benefit from revascularization procedures, in terms of improvement of left ventricular (LV) function, alleviation of heart failure symptoms, and improvement of long-term prognosis. However, the restricted availability of PET equipment cannot meet the increasing demand for viability studies. As a consequence, much effort has been invested over the past years in the development of 511-keV collimators, enabling FDG imaging with single-photon emission computed tomography (SPECT). Because SPECT cameras are widely available, this approach may allow a more widespread use of FDG for the assessment of myocardial viability. Initial studies have directly compared FDG-SPECT with FDG-PET and consistently reported a good agreement for the assessment of myocardial viability between these 2 techniques. Additional studies have shown that FDG-SPECT can also predict improvement of LV function and heart failure symptoms after revascularization. Finally, recent developments, including coincidence imaging and attenuation correction, may further optimize cardiac FDG imaging (for the assessment of viability) without PET systems.

Publication types

  • Review

MeSH terms

  • Coronary Disease / diagnostic imaging*
  • Coronary Disease / metabolism
  • Coronary Disease / therapy
  • Fluorodeoxyglucose F18* / pharmacokinetics
  • Heart / diagnostic imaging*
  • Heart Diseases / diagnostic imaging*
  • Heart Diseases / metabolism
  • Heart Diseases / therapy
  • Humans
  • Myocardial Revascularization
  • Myocardium / metabolism
  • Prognosis
  • Radiopharmaceuticals* / pharmacokinetics
  • Tomography, Emission-Computed*
  • Tomography, Emission-Computed, Single-Photon*
  • Ventricular Function, Left

Substances

  • Radiopharmaceuticals
  • Fluorodeoxyglucose F18