Assessment of left ventricular function by gated myocardial perfusion and gated blood-pool SPECT: can we use the same reference database?

Ann Nucl Med. 2000 Apr;14(2):75-80. doi: 10.1007/BF02988584.

Abstract

The purpose of this study was to compare left ventricular (LV) volume and ejection fraction (LVEF) measurements obtained with electrocardiographic gated single-photon emission computed tomographic (SPECT) myocardial perfusion imaging (GS-MPI) with those obtained with gated SPECT cardiac blood-pool imaging (GS-pool). Fifteen patients underwent GS-MPI with technetium-99m-tetrofosmin and GS-pool with technetium-99m-erythrocyte, within a mean interval of 8 +/- 3 days. Eight patients had suspected dilated cardiomyopathy and seven patients had angiographically significant coronary artery disease. End-diastolic volume (EDV), end-systolic volume (ESV) and LVEF measurements were estimated from GS-MPI images by means of Cedars-Sinai automatic quantitative program and from GS-pool images by the threshold technique. Mean differences between GS-MPI and GS-pool in EDV, ESV and LVEF measurements were -2.8 +/- 10.5 ml [95% confidence interval (CI): -8.6 +/- 3.0 ml], 2.6 +/- 7.3 ml (CI: -1.4 +/- 6.6 ml) and -2.3 +/- 5.1% (CI: -5.1 +/- 0.6%), respectively. No significant difference in the mean differences from 0 was found for EDV, ESV or LVEF measurements. Bland-Altman plots revealed no trend over the measured LV volumes and LVEF. For all parameters, regression lines approximated lines of identity. The excellent agreement between GS-MPI and GS-pool measurements suggests that, for estimation of LV volumes and LVEF, these two techniques may be used interchangeably and measurements by one method can serve as a reference for the other.

Publication types

  • Comparative Study

MeSH terms

  • Adult
  • Aged
  • Cardiomyopathy, Dilated / diagnostic imaging
  • Coronary Disease / diagnostic imaging
  • Databases, Factual
  • Female
  • Gated Blood-Pool Imaging / methods*
  • Gated Blood-Pool Imaging / standards
  • Gated Blood-Pool Imaging / statistics & numerical data
  • Humans
  • Male
  • Middle Aged
  • Organophosphorus Compounds
  • Organotechnetium Compounds
  • Phantoms, Imaging
  • Radiopharmaceuticals
  • Reference Values
  • Technetium
  • Tomography, Emission-Computed, Single-Photon / methods*
  • Tomography, Emission-Computed, Single-Photon / standards
  • Tomography, Emission-Computed, Single-Photon / statistics & numerical data
  • Ventricular Function, Left*

Substances

  • Organophosphorus Compounds
  • Organotechnetium Compounds
  • Radiopharmaceuticals
  • technetium tc-99m tetrofosmin
  • Technetium