A modified treadmill exercise protocol for computer-assisted analysis of the ST segment/heart rate slope: Methods and reproducibility

https://doi.org/10.1016/S0022-0736(86)81058-5Get rights and content

Summary

A new treadmill exercise protocol, modified from the standard Bruce method, was designed to improve ST segment/heart rate slope accuracy and applicability by reducing heart rate increments between exercise stages. In 150 patients exercised according to the new protocol and in 150 patients exercised according to the Bruce protocol, similar exercise tolerance and similar overall heart rate, systolic blood pressure and double product responses to exercise were observed. The mean increment in heart rate between exercise stages of the new protocol was ten beats/minute, which was significantly lower than the 27 beats/minute/stage found with the Bruce protocol. The accuracy of computer-measured ST segment depression was validated by comparison with physician measurement in a separate subgroup of patients with angina pectoris, and serial testing demonstrated stronger interest reproducibility for the ST segment/heart rate slope than for either measured ST setment depression, peak heart rate achieved or duration of exercise.

References (22)

  • MS Elamin et al.

    Prediction of severity of coronary artery disease using slope of submaximal ST segment/heart rate relationship

    Cardiovasc Res

    (1980)
  • Cited by (98)

    • Transient recovery of epicardial and torso ST-segment ischemic signals during cardiac stress tests: A possible physiological mechanism

      2021, Journal of Electrocardiology
      Citation Excerpt :

      Cardiac stress was induced using right atrial pacing at elevated rates or pharmacological stimulation via dobutamine infusion. Typical clinical protocols were used for target pacing and drug infusion rates [12,13]. Each episode of ischemia lasted 15 min with a fixed level of occlusion, which was determined on an experiment by experiment basis by the animal stability.

    • The association between insomnia symptoms and cardiovascular risk factors in patients who complete outpatient cardiac rehabilitation

      2017, Sleep Medicine
      Citation Excerpt :

      One MET (3.5 ml O2/kg body weight × min) approximates the amount of oxygen required at rest [26]. Peak METs were estimated by recording treadmill grade and speed upon termination of the standardized exercise stress test (Bruce or Modified Bruce Protocol) [27,28] using an established equation [29]. Peak METs were used to categorize individuals as low fitness (<5 METs), moderate fitness (5–8 METs), or high fitness (>8 METs; [30]).

    • Short-coupled polymorphic ventricular tachycardia at rest linked to a novel ryanodine receptor (RyR2) mutation: Leaky RyR2 channels under non-stress conditions

      2015, International Journal of Cardiology
      Citation Excerpt :

      Information from echocardiography studies, Holter and event monitors, hospital telemetry, and electrophysiology studies were recorded. Treadmill stress tests were performed using the Cornell protocol [8]. Written informed consent was obtained from family members who agreed to have blood samples obtained for genetic evaluation.

    View all citing articles on Scopus
    1

    From the Division of Cardiology, Department of Medicine, The New York Hospital-Cornell Medical Center, 525 East 68th Street, New York, New York 10021.

    View full text