The value, limitations, and applications of nuclear dacryocystography

https://doi.org/10.1016/S0001-2998(81)80022-0Get rights and content

Nuclear dacryocystography is a simple, relatively harmless method of evaluating patients suspected of having abnormalities of the nasolacrimal drainage system. A drop of normal saline containing approximately 100 μCi of 99mTc-pertechnetate is placed on the conjunctiva near the lateral canthus, and serial scintigrams are obtained as the pertechnetate flows along the tear strips, through the nasolacrimal drainage system, into the nasal fossa. By using a pinhole collimator with a very small aperture (1 mm), the canaliculi, the nasolacrimal sac, and the nasolacrimal duct are readily visualized. When flow is impaired, the site of obstruction can often be identified. Contrast dacryocystography provides similar information but requires the injection of contrast material directly into a canaliculus. Nuclear dacryocystography provides good functional assessment of nasolacrimal drainage but has serious shortcomings in defining pathologic anatomy. Contrast dacryocystography outlines the anatomy well but often misses minor obstructions. The two studies are complementary and together provide an effective means of evaluating the nasolacrimal drainage system.

References (13)

  • RossomondoRM et al.

    A new method of evaluating lacrimal drainage

    Arch Ophthalmol

    (1972)
  • CarltonWH et al.

    Clinical evaluation of microscintigraphy of the lacrimal drainage apparatus

    J Nucl Med

    (1973)
  • BrizelHE et al.

    The effects of radiotherapy on the nasolacrimal system as evaluated by dacryoscintigraphy

    Radiology

    (1975)
  • El Gammal T, Brooks BS: Biplane magnification and subtraction Amipaque dacryocystography: A technical note. Radiology...
  • GullottaU et al.
  • Trueblood JH, Dunn JW: Personal communication, March...
There are more references available in the full text version of this article.

Cited by (28)

  • Neuroimaging of Adult Lacrimal Drainage System

    2021, Current Problems in Diagnostic Radiology
    Citation Excerpt :

    Dacryoscintigraphy provides a noninvasive, sensitive, and tolerable method for assessment of the physiologic tear outflow and pathologic epiphora.14 However, dacryoscintigraphy have major shortcomings including poor spatial resolution, anatomy assessment, and extent/detection of extrinsic masses.15 Contrast dacryocystography (DCG), was historically considered by many the primary study for evaluation of epiphora when no mass is suspected.16

  • Dispensing and administration of radiopharmaceuticals for dacryoscintigraphy

    2006, Journal of the American Pharmacists Association
    Citation Excerpt :

    Several chemical forms of Tc-99m radiopharmaceuticals have been used for dacryoscintigraphy. Although Tc-99m sodium pertechnetate has been most common,1,3,5,9,11–15,17–19 Tc-99m colloids such as sulfur colloid,2,6,8,16 albumin colloid,7 and tin colloid 4,10 have also been used. Each of these is equally successful in producing high-quality diagnostic images of transit through the lacrimal duct.

  • Nuclear dacryoscintigraphy. Its role in oral and maxillofacial surgery

    1995, Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology and
View all citing articles on Scopus
View full text