Renal clearance determination with one blood sample: Improved accuracy and universal applicability by a new calculation principle

https://doi.org/10.1016/S0001-2998(05)80064-9Get rights and content

A sufficiently accurate quantification of renal function requiring only one plasma sample without an additional gamma camera study has until now only been possible in adults. A new principle has been developed that allows the universal application of known algorithms, irrespective of the clearance substance used, by normalizing the plasma concentrations with respect to individual body dimensions of adult as well as infant patients. In this respect, algorithms are established for clearance determinations using technetium-99m mercaptoacetyltriglycine which are based on steady-state studies as the reference. They allow the calculation of quantitative clearance values in infants and require the drawing of only one blood sample at any time between 25 and 40 minutes postinjection. The comparison with a combined-camera/two-plasma-sample technique performed in 46 children ranging in age from 9 days to 14 years (mean, 6.05 years) resulted in a standard deviation of 8.5% from the line of identity (r=0.94). Moreover, this procedure also increases accuracy in adult patients, especially those with impaired renal function.

References (50)

  • RussellCD et al.

    Measurement of glomerular filtration rate: Single injection plasma clearance method without urine collection

    J Nucl Med

    (1985)
  • TepePG et al.

    Comparison of measurement of glomerular filtration rate by single sample, plasma disappearance slope/intercept and other methods

    Eur J Med

    (1987)
  • MulliganJS et al.

    Methods for measuring GFR with technetium-99m-DTPA: An analysis of several common methods

    J Nucl Med

    (1990)
  • TauxeWN

    Determination of glomerular filtration rate by single-plasma sampling technique following injection of radioiodinated diatrizoate

    J Nucl Med

    (1986)
  • TauxeWN et al.

    Effective renal plasma flow: Estimation from theoretical volumes of distribution of intravenously injected 131 I-orthoiodohippurate

  • TauxeWN et al.

    New formulas for the calculation of effective renal plasma flow

    Eur J Nucl Med

    (1982)
  • RussellCD et al.

    Estimation of technetium-99m-MAG3 plasma clearance in adults from one or two blood samples

    J Nucl Med

    (1989)
  • BubeckB

    Technetium-99m-MAG3 für die nuklearmedizinische Nierenfunktionsdiagnostik

  • SapirsteinLA et al.

    Volumes of distribution and clearances of intravenously injected creatinine in the dog

    Am J Physiol

    (1955)
  • RussellCD et al.

    Measurements of renal function with radionuclides

    J Nucl Med

    (1989)
  • BlaufoxMD

    Procedures of choice in renal nuclear medicine

    J Nucl Med

    (1991)
  • PiepszA et al.

    Paediatric nuclear medicine

    Eur J Nucl Med

    (1991)
  • ShoreRM

    Glomerular filtration rate in children: Where we have been: where we are going

    J Nucl Med

    (1991)
  • GordonI et al.

    Estimation of technetium-99m-MAG3 renal clearance in children: Two gamma camera techniques compared with multiple plasma samples

    J Nucl Med

    (1991)
  • TauxeWN et al.

    Estimation of effective renal plasma flow in children by use of a single plasma sample after injection of orthoiodohippurate

  • TauxeWN et al.

    Single-sample method for the estimation of glomerular filtration rate in children

    J Nucl Med

    (1987)
  • HamHR et al.

    Estimation of glomerular filtration rate in infants and in children using a single-plasma sample method

    J Nucl Med

    (1991)
  • WhiteAJ et al.

    Normalisation of glomerular filtration rate measurements

    Eur J Med

    (1991)
  • SummervilleDA et al.

    The use of radiopharmaceuticals in the measurement of glomerular filtration rate: A review

  • BubeckB et al.

    Renal function studies using 99mTc-MAG3: Pharmacokinetics and slope clearance determination

  • NadlerSB et al.

    Prediction of blood in normal human adults

    Surgery

    (1962)
  • RetzlaffJA et al.

    Erythrocyte volume, plasma volume, and lean body mass in adult men and women

    Blood

    (1969)
  • DissmannT et al.

    Das Erythrocyten- und Plasmavolumen sowie die Relation zwischen Körperhämatokrit und venösem Hämatokrit in verschiedenen Stadien der essentiellen und bei renovasculärer Hypertonie

    Klin Wschr

    (1971)
  • BoerP

    Estimated lean body mass as an index for normalization of body fluid volumes in humans

    Am J Physiol

    (1984)
  • HagstamKE et al.

    Comparison of methods for determination of glomerular filtration rate in renal disease

    Scand J Clin Lab Invest

    (1974)
  • Cited by (49)

    • Imaging in Renal Transplants: An Update

      2021, Seminars in Nuclear Medicine
    • Peri- and Postsurgical Evaluations of Renal Transplant

      2017, Seminars in Nuclear Medicine
      Citation Excerpt :

      For this purpose, most commonly used radiopharmaceuticals are iothalamate, 51Cr-EDTA, and 99mTc-DTPA, which their plasma clearance reflects of the GFR. 131-OIH has been used for the measurement of effective renal plasma flow (ERPF) for a long time; however, since 1990, 131-OIH has been replaced by other tubular agents such as 99mTc-MAG3 and 99mTc-EC.9,10 Several methods for the calculation of renal clearance of those radiopharmaceuticals have been described, including the use of multiple- or single-plasma sampling with or without urinary sampling.

    • Renal Function Assessment During Peptide Receptor Radionuclide Therapy

      2016, Seminars in Nuclear Medicine
      Citation Excerpt :

      Its clearance is approximately 50%-60% of ortho iodo hippurate (OIH), which is a well-known measure for effective renal plasma flow, and more than twice than that of 99mTc-DTPA. A simplified equation of TER measurement was introduced for a single-injection single-sample measurement method,20 as well as for 99mTc-EC.21,22 There is also gamma-camera-based clearance measurement method for 99mTc-MAG, which was found superior to creatinine clearance to monitor the renal functional changes.23

    • Decision Support Systems in Diuresis Renography

      2008, Seminars in Nuclear Medicine
      Citation Excerpt :

      The mean camera-based MAG3 clearance corrected for body surface area was 321 ± 69 mL/min/1.73 m2 (Table 3). Clearance measurements can aid in the interpretation of the renogram and facilitate appropriate patient management.6,38,49-52 Plasma sample clearance methods are considered to be superior to camera-based clearances6 and MAG3 clearances can be calculated with reasonable accuracy from a single plasma sample obtained 40 to 45 minutes after injection51,52; however, informal surveys indicate that nuclear radiology services in the United States rarely offer plasma sample clearances because of the additional technical expertise required to perform a plasma sample measurement and the necessity of complying with CLIA (Clinical Laboratory Improvement Act) regulations required for in vitro plasma sample clearances.

    View all citing articles on Scopus
    View full text