Technetium-99m tetrofosmin for parathyroid scintigraphy: a direct comparison with 99mTc-MIBI, 201Tl, MRI and US

  • Original Article
  • Published:
European Journal of Nuclear Medicine Aims and scope Submit manuscript

Abstract

The aim of this study was to evaluate the efficacy and role of technetium-99m tetrofosmin for the detection of abnormal parathyroid glands to be referred for surgical treatment. Twenty-eight consecutive patients, including 25 primary and 3 secondary cases of hyperparathyroidism, were evaluated. 99mTc-tetrofosmin/99mTc-pertechnetate subtraction scintigraphy (TF/Tc) was performed on all patients, and the results were directly compared with those of 99mTc-methoxyisobutylisonitrile (MIBI)/99mTc-pertechnetate subtraction scintigraphy (MIBI/Tc), 201Tl/99mTc-pertechnetate subtraction scintigraphy (Tl/Tc), magnetic resonance imaging (MRI) and ultrasonography (US). In cases of single-gland disease, the sensitivities of TF/Tc, MIBI/Tc, Tl/Tc, MRI and US were 63.2%, 68.4%, 57.9%, 55.6% and 63.2%, respectively. In cases of multi-gland disease, the sensitivities of TF/Tc, MIBI/Tc, Tl/Tc, MRI and US were 41.7%, 41.7%, 37.5%, 58.3% and 54.2%, respectively. In cases of parathyroid adenoma, the sensitivities of TF/Tc, MIBI/Tc, Tl/Tc, MRI and US were 68.8%, 75.0%, 68.8%, 62.5% and 75.0%, respectively. In cases of parathyroid hyperplasia, the sensitivities of TF/Tc, MIBI/Tc, Tl/Tc, MRI and US were 40.7%, 40.7%, 33.3%, 53.8% and 48.1%, respectively. It is concluded that, for the detection of abnormal parathyroid glands, 99mTc-tetrofosmin is as useful as 99mTc-MIBI and is more useful than 201Tl.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Received 9 June and in revised form 14 July 2001

Electronic Publication

Rights and permissions

Reprints and permissions

About this article

Cite this article

Wakamatsu, H., Noguchi, S., Yamashita, H. et al. Technetium-99m tetrofosmin for parathyroid scintigraphy: a direct comparison with 99mTc-MIBI, 201Tl, MRI and US. Eur J Nucl Med 28, 1817–1827 (2001). https://doi.org/10.1007/s002590100627

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s002590100627

Navigation