Skip to main content
Log in

Comparison of clinical data sets acquired on different tomographs using 6-18F-l-dopa

  • Original article
  • Published:
European Journal of Nuclear Medicine Aims and scope Submit manuscript

Abstract.

Longitudinal positron emission tomography (PET) studies of 6-18F-l-dopa uptake in the striatum are used to assess the progression of Parkinson’s disease or the survival of neuronal cells grafted in parkinsonian patients. These studies are performed over several years, and data analysis may suffer from the change from old tomographs to new machines with better sensitivity and spatial resolution. Furthermore, such studies on parkinsonian patients may be accomplished in either 2D or 3D acquisition mode. The aforementioned improvements offer great benefits for the study of neurodegenerative diseases, especially those affecting the striatum. However, direct comparison of data is not straightforward owing to variation in scanner characteristics. In this study, we assessed the feasibility of comparing the 6-18F-l-dopa striatal uptake values (K c) measured in two groups of healthy subjects using two tomographs of different generations.We re-studied and compared acquisitions performed on 14 healthy subjects using 6-18F-l-dopa. Half of these studies had been performed in 2D acquisition mode using an ECAT 953B. The other half had been performed in 3D acquisition mode using an ECAT EXACT HR+. Different reconstruction protocols were used and the K c values obtained were statistically compared.The results showed that lowering the transverse spatial resolution of images obtained with the scanner having the better spatial resolution, so that it more closely matched that of the other machine, allowed similar K c values to be obtained in healthy subjects.This study shows that quantitative results of 6-18F-l-dopa scans can be matched between different scanners with different intrinsic resolutions. This can be accomplished using adequate modifications of the reconstruction parameters. Such modifications can be used to help in the longitudinal monitoring of parkinsonian patients using different tomographs.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Received 23 November 1999 and in revised form 2 February 2000

Rights and permissions

Reprints and permissions

About this article

Cite this article

Ribeiro, MJ., Remy, P., Bendriem, B. et al. Comparison of clinical data sets acquired on different tomographs using 6-18F-l-dopa. Eur J Nucl Med 27, 707–712 (2000). https://doi.org/10.1007/s002590050566

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/s002590050566

Navigation