Skip to main content

Advertisement

Log in

Use of technetium-99m sestamibi ECG-gated single-photon emission tomography for the evaluation of left ventricular function following coronary artery bypass graft: comparison with three-dimensional magnetic resonance imaging

  • Original article
  • Published:
European Journal of Nuclear Medicine Aims and scope Submit manuscript

Abstract.

In patients who had undergone cardiac surgery (coronary artery bypass graft) and whose hearts showed abnormal movement during the cardiac cycle, we studied the accuracy of functional assessment using ECG-gated single-photon emission tomography (SPET) and the automated software developed by Germano et al. by comparing the findings with magnetic resonance (MR) images acquired three-dimensionally. Sixteen patients who had undergone cardiac surgery underwent 99mTc-sestamibi gated SPET (MIBI-g-SPET) and MRI on the same day. Left ventricular end-diastolic and end-systolic volumes (EDV, ESV) and ejection fraction (LVEF) were measured using MIBI-g-SPET and the aforementioned algorithm. Regional wall thickening was assessed using a four-point scale on MIBI-g-SPET and cine MRI. There was a good correlation between MIBI-g-SPET and MRI in respect of EDV (r=0.89), ESV (r=0.93) and LVEF (r=0.89). A high degree of agreement was found between the wall thickening scores obtained by MIBI-g-SPET and MRI in total segments (κ=0.62) and in septal segments (κ=0.67). It is concluded that ECG-gated perfusion SPET can provide regional and global functional information, including absolute volumes, in patients following cardiac surgery.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Received 5 January and in revised form 18 March 1999

Rights and permissions

Reprints and permissions

About this article

Cite this article

Tadamura, E., Kudoh, T., Motooka, M. et al. Use of technetium-99m sestamibi ECG-gated single-photon emission tomography for the evaluation of left ventricular function following coronary artery bypass graft: comparison with three-dimensional magnetic resonance imaging. Eur J Nucl Med 26, 705–712 (1999). https://doi.org/10.1007/s002590050441

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/s002590050441

Navigation