Skip to main content

Advertisement

Log in

Respiratory and cardiac motion correction with 4D PET imaging: shooting at moving targets

  • Focus on
  • Published:
European Journal of Nuclear Medicine and Molecular Imaging Aims and scope Submit manuscript

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

References

  1. Li G, Citrin D, Camphausen K, Mueller B, Burman C, Mychalczak B, et al. Advances in 4D medical imaging and 4D radiation therapy. Technol Cancer Res Treat 2008;7(1):67–81. Feb.

    PubMed  CAS  Google Scholar 

  2. Hamill JJ, Bosmans G, Dekker A. Respiratory-gated CT as a tool for the simulation of breathing artifacts in PET and PET/CT. Med Phys 2008;35(2):576–85. Feb.

    Article  PubMed  CAS  Google Scholar 

  3. Dawood M, Buther F, Jiang X, Schafers KP. Respiratory motion correction in 3-D PET data with advanced optical flow algorithms. IEEE Trans Med Imaging 2008;27(8):1164–75. Aug.

    Article  PubMed  Google Scholar 

  4. Park SJ, Ionascu D, Killoran J, Mamede M, Gerbaudo VH, Chin L, et al. Evaluation of the combined effects of target size, respiratory motion and background activity on 3D and 4D PET/CT images. Phys Med Biol 2008;53(13):3661–79. Jul 7.

    Article  PubMed  Google Scholar 

  5. Brahme A, Nyman P, Skatt B. 4D laser camera for accurate patient positioning, collision avoidance, image fusion and adaptive approaches during diagnostic and therapeutic procedures. Med Phys 2008;35(5):1670–81. May.

    Article  PubMed  Google Scholar 

  6. Vines DC, Keller H, Hoisak JD, Breen SL. Quantitative PET comparing gated with nongated acquisitions using a NEMA phantom with respiratory-simulated motion. J Nucl Med Technol 2007;35(4):246–51. Dec.

    Article  PubMed  Google Scholar 

  7. Schäfers KP, Stegger L. Combined imaging of molecular function and morphology with PET/CT and SPECT/CT: image fusion and motion correction. Basic Res Cardiol 2008;103(2):191–9. Mar.

    Article  PubMed  Google Scholar 

  8. Khurshid K, McGough RJ, Berger K. Automated cardiac motion compensation in PET/CT for accurate reconstruction of PET myocardial perfusion images. Phys Med Biol 2008;53(20):5705–18. Oct 21.

    Article  PubMed  Google Scholar 

  9. McQuaid SJ, Hutton BF. Sources of attenuation-correction artefacts in cardiac PET/CT and SPECT/CT. Eur J Nucl Med Mol Imaging 2008;35(6):1117–23. Jun.

    Article  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Giovanni Lucignani.

Additional information

“Focus on…” abridgements aim to highlight papers published within the past year and draw extensively on the texts and summaries of the articles referenced. Less recent citations are also included when deemed useful to provide background information on the topic reviewed.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Lucignani, G. Respiratory and cardiac motion correction with 4D PET imaging: shooting at moving targets. Eur J Nucl Med Mol Imaging 36, 315–319 (2009). https://doi.org/10.1007/s00259-008-1017-5

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00259-008-1017-5

Keywords

Navigation