A publicly accessible Monte Carlo database for validation purposes in emission tomography

  • Short Communication
  • Published:
European Journal of Nuclear Medicine and Molecular Imaging Aims and scope Submit manuscript

Abstract

Monte Carlo (MC) methods provide ideal data sets to assess reconstruction and correction techniques in emission tomography (ET). Although several ET-dedicated MC codes are available, their use is hindered by the heavy computation burden required for high statistics simulations as well as by the need to adapt the code to the purpose of the individual user. In this work a publicly accessible database of MC-simulated ET data sets (the MC-ET database) was created and published on an Internet web site (http://www.ibfm.cnr.it/mcet/index.html), in order to provide MC-simulated data ready to be downloaded and used by researchers at different sites with similar evaluation purposes. At present, the MC-ET database provides direct access to MC-simulated raw data of unscattered, scattered and total events: (a) obtained by different MC codes, (b) relative to different radioactive sources, from simple geometrical phantoms to studies of normal and pathological subjects and (c) derived from different SPECT and PET scanners. The main features of the MC-ET data sets are: (a) validation by comparison with measured data, (b) classification according to pre-defined database characteristics, (c) common-use file format and (d) easy and free access and download.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4

References

  1. Ljungberg M, Strand SE. A Monte Carlo program for the simulation of scintillation camera characteristics. Comput Methods Prog Biomed 1989;29:257–72

    CAS  Google Scholar 

  2. Thompson CJ, Cantu JM, Picard Y. PETSIM: Monte Carlo program simulation of all sensitivity and resolution parameters of cylindrical positron imaging systems. Phys Med Biol 1992;37:731–49

    CAS  PubMed  Google Scholar 

  3. Harrison RL, Vannoy SD, Haynor DR, Gillipsie SB, Kaplan MS, Lewellen TK. Preliminary experience with the photon history generator module of a public domain simulation system for emission tomography. In: Proceedings of the IEEE Nuclear Science Symposium and Medical Imaging Conference. San Francisco, 1993:1154–8

  4. Zaidi H, Labbé C, Morel C. EIDOLON: implementation of an environment for Monte Carlo simulation of fully 3D positron tomography on a high-performance parallel platform. Parallel Comput 1998;24:1523–36

    Google Scholar 

  5. Castiglioni I, Cremonesi O, Gilardi MC, Savi A, Rizzo G, Bettinardi V, et al. A Monte Carlo model of noise components in 3-d PET. IEEE Trans Nucl Sci 2002;49:2297–303

    Google Scholar 

  6. Jan S, Santin G, Strul D, Staelens S, Assiè K, Autret D, et al. GATE: a simulation toolkit for PET and SPECT. Phys Med Biol 2004;49:4543–61

    CAS  PubMed  Google Scholar 

  7. Castiglioni I, Cremonesi O, Gilardi MC, Bettinardi V, Savi A, Bellotti E, et al. Scatter correction techniques in 3D PET: a Monte Carlo evaluation. IEEE Trans Nucl Sci 1999;46:2053–8

    Google Scholar 

  8. el Fakhri GN, Buvat I, Pelegrini M, Benali H, Almeida P, Bendriem B, et al. Respective roles of scatter, attenuation, depth-dependent collimator response and finite spatial resolution in cardiac single-photon emission tomography quantitation: a Monte Carlo study. Eur J Nucl Med 1999;26 5:437–46

    PubMed  Google Scholar 

  9. Soret M, Koulibaly PM, Darcourt J, Hapdey S, Buvat I. Quantitative accuracy of dopaminergic neurotransmission imaging with 123I SPECT. J Nucl Med 2003;44 7:1184–93

    CAS  PubMed  Google Scholar 

  10. Zubal IG, Harrell CR, Smith E. Computerized 3D segmented human anatomy. Med Phys 1994;21:299–302

    CAS  PubMed  Google Scholar 

  11. Deloar HM, Fujiwara T, Shidahara M, Nakamura T, Watabe H, Narita Y, et al. Estimation of absorbed dose for 2-[F-18]fluoro-2-deoxy-d-glucose using whole-body PET and magnetic resonance imaging, Eur J Nucl Med 1998;25:565–74

    CAS  PubMed  Google Scholar 

Download references

Acknowledgements

This work was supported by the Galileo/Egide Program (project n. 04368WF).

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to I. Castiglioni.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Castiglioni, I., Buvat, I., Rizzo, G. et al. A publicly accessible Monte Carlo database for validation purposes in emission tomography. Eur J Nucl Med Mol Imaging 32, 1234–1239 (2005). https://doi.org/10.1007/s00259-005-1832-x

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00259-005-1832-x

Keywords

Navigation