Validation of 4D-MSPECT and QGS for quantification of left ventricular volumes and ejection fraction from gated 99mTc-MIBI SPET: comparison with cardiac magnetic resonance imaging

  • Original Article
  • Published:
European Journal of Nuclear Medicine and Molecular Imaging Aims and scope Submit manuscript

Abstract

The main aim of this study was to validate the accuracy of 4D-MSPECT in the assessment of left ventricular (LV) end-diastolic/end-systolic volumes (EDV, ESV) and ejection fraction (LVEF) from gated technetium-99m methoxyisobutylisonitrile single-photon emission tomography (99mTc-MIBI SPET), using cardiac magnetic resonance imaging (cMRI) as the reference method. By further comparing 4D-MSPECT and QGS with cMRI, the software-specific characteristics were analysed to elucidate clinical applicability. Fifty-four patients with suspected or proven coronary artery disease (CAD) were examined with gated 99mTc-MIBI SPET (8 gates/cardiac cycle) about 60 min after tracer injection at rest. LV EDV, ESV and LVEF were calculated from gated 99mTc-MIBI SPET using 4D-MSPECT and QGS. On the same day, cMRI (20 gates/cardiac cycle) was performed, with LV EDV, ESV and LVEF calculated using Simpson’s rule. Both algorithms worked with all data sets. Correlation between the results of gated 99mTc-MIBI SPET and cMRI was high for EDV [R=0.89 (4D-MSPECT), R=0.92 (QGS)], ESV [R=0.96 (4D-MSPECT), R=0.96 (QGS)] and LVEF [R=0.89 (4D-MSPECT), R=0.90 (QGS)]. In contrast to ESV, EDV was significantly underestimated by 4D-MSPECT and QGS compared to cMRI [130±45 ml (4D-MSPECT), 122±41 ml (QGS), 139±36 ml (cMRI)]. For LVEF, 4D-MSPECT and cMRI revealed no significant differences, whereas QGS yielded significantly lower values than cMRI [57.5%±13.7% (4D-MSPECT), 52.2%±12.4% (QGS), 60.0%±15.8% (cMRI)]. In conclusion, agreement between gated 99mTc-MIBI SPET and cMRI is good across a wide range of clinically relevant LV volume and LVEF values assessed by 4D-MSPECT and QGS. However, algorithm-varying underestimation of LVEF should be accounted for in the clinical context and limits interchangeable use of software.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2 A, C
Fig. 3 A, C
Fig. 4 A, C
Fig. 5 A, C, E

Similar content being viewed by others

References

  1. Hammermeister KE, de Rouen TA, Dodge HT. Variables predictive of survival in patients with coronary disease. Selection by univariate and multivariate analyses from the clinical, electrocardiographic, exercise, arteriographic, and quantitative angiographic evaluations. Circulation 1979; 59:421–430.

    CAS  PubMed  Google Scholar 

  2. White HD, Norris RM, Brown MA, Brandt PW, Whitlock M, Wild CJ. Left ventricular end-systolic volume as the major determinant of survival after recovery from myocardial infarction. Circulation 1987; 76:44–51.

    CAS  PubMed  Google Scholar 

  3. Yamaguchi A, Ino T, Adachi H, Murata S, Kamio H, Okada M, Tsuboi J. Left ventricular volume predicts postoperative course in patient with ischemic cardiomyopathy. Ann Thorac Surg 1998; 65:434–438.

    Article  CAS  PubMed  Google Scholar 

  4. Allman KC, Shaw LJ, Hachamovitch R, Udelson JE. Myocardial viability testing and impact of revascularization on prognosis in patients with coronary artery disease and left ventricular dysfunction: a meta-analysis. J Am Coll Cardiol 2002; 39:1151–1158.

    Article  PubMed  Google Scholar 

  5. Cleland JGF, Pennell DJ, Ray SG, Coats AJ, Macfarlane PW, Murray GD, Dalle Mule J, Vered Z, Lahiri A. Myocardial viability as a determinant of the ejection fraction response to carvedilol in patients with heart failure (CHRISTMAS trial): randomised controlled trial. Lancet 2003; 362:14–21.

    Article  CAS  PubMed  Google Scholar 

  6. Smanio PE, Watson DD, Segalla DL, Vinson EL, Smith WH, Beller GA. Value of gating of technetium-99m sestamibi single-photon emission computer tomographic imaging. J Am Coll Cardiol 1997; 30:1687–1692.

    Google Scholar 

  7. Germano G, Kiat H, Kavanagh PB, Moriel M, Mazzanti M, Su HAT, Van Train KF, Berman DS. Automatic quantification of ejection fraction from gated myocardial perfusion SPECT. J Nucl Med 1995; 36:2138–2147.

    PubMed  Google Scholar 

  8. Iskandrian AE, Germano G, VanDecker W, Ogilby JD, Wolf N, Mintz R, Berman DS. Validation of left ventricular volume measurements by gated SPECT99mTc-labeled sestamibi imaging. J Nucl Cardiol 1998; 5:574–578.

    CAS  PubMed  Google Scholar 

  9. Ficaro EP, Quaife RA, Kritzman JN, Corbett JR. Accuracy and reproducibility of 3D-MSPECT for estimating left ventricular ejection fraction in patients with severe perfusion abnormalities [abstract]. Circulation 1999; 100 (Suppl I):I26.

    Google Scholar 

  10. DePuey EG, Rozanski A. Using gated technetium-99m-sestamibi SPECT to characterize fixed myocardial defects as infarct or artifact. J Nucl Med 1995; 36:952–955.

    CAS  PubMed  Google Scholar 

  11. Sharir T, Germano G, Kavanagh PB, Lai S, Cohen I, Lewin HC, Friedman JD, Zellweger MJ, Berman DS. Incremental prognostic value of post-stress left ventricular ejection fraction and volume by gated myocardial perfusion single photon emission computed tomography. Circulation 1999; 100:1035–1042.

    CAS  PubMed  Google Scholar 

  12. Ioannidis JP, Trikalinos TA, Danias PG. Electrocardiogram-gated single-photon emission computed tomography versus cardiac magnetic resonance imaging for the assessment of left ventricular volumes and ejection fraction: a meta-analysis. J Am Coll Cardiol 2002; 39:2059–2068.

    Google Scholar 

  13. Kondo C, Fukushima K, Kusakabe K. Measurement of left ventricular volumes and ejection fraction by quantitative gated SPET, contrast ventriculography and magnetic resonance imaging: a meta-analysis. Eur J Nucl Med Mol Imaging 2003; 30:851–858.

    PubMed  Google Scholar 

  14. Bavelaar-Croon CDL, Kayser HWM, van der Wall EE, de Roos A, Dibbets-Schneider P, Pauwels EK, Germano G, Atsma DE. Left ventricular function: correlation of quantitative gated SPECT and MR imaging over a wide range of values. Radiology 2000; 217:572–575.

    CAS  PubMed  Google Scholar 

  15. Bax JJ, Lamb H, Dibbets P, Pelikan H, Boersma E, Viergever EP, Germano G, Vliegen HW, de Roos A, Pauwels EK, Van der Wall EE. Comparison of gated single-photon emission computed tomography with magnetic resonance imaging for evaluation of left ventricular function in ischemic cardiomyopathy. Am J Cardiol 2000; 86:1299–1305.

    CAS  PubMed  Google Scholar 

  16. Tadamura E, Kudoh T, Motooka M, Inubushi M, Shirakawa S, Hattori N, Okada T, Matsuda T, Koshiji T, Nishimura K, Matsuda K, Konishi J. Assessment of regional and global left ventricular function by reinjection Tl-201 and rest Tc-99m sestamibi ECG-gated SPECT. J Am Coll Cardiol 1999; 33:991–997.

    CAS  PubMed  Google Scholar 

  17. Tadamura E, Kudoh T, Motooka M, Inubushi M, Okada T, Kubo S, Hattori N, Matsuda T, Koshiji T, Nishimura K, Komeda M, Konishi J. Use of technetium-99m sestamibi ECG-gated single-photon emission tomography for the evaluation of left ventricular function following coronary artery bypass graft: comparison with three-dimensional magnetic resonance imaging. Eur J Nucl Med 1999; 26:705–712.

    CAS  PubMed  Google Scholar 

  18. Thorley PJ, Plein S, Bloomer TN, Ridgway JP, Sivananthan UM. Comparison of99mTc tetrofosmin gated SPECT measurements of left ventricular volumes and ejection fraction with MRI over a wide range of values. Nucl Med Commun 2003; 24:763–769.

    Article  CAS  PubMed  Google Scholar 

  19. Vaduganathan P, He Z, Vick GW III, Mahmarian JJ, Verani MS. Evaluation of left ventricular wall motion, volumes, and ejection fraction by gated myocardial tomography with technetium 99m-labeled tetrofosmin: a comparison with cine magnetic resonance imaging. J Nucl Cardiol 1998; 6:3–10.

    Google Scholar 

  20. Faber TL, Vansant JP, Pettigrew RI, Galt JR, Blais M, Chatzimavroudis G, Cooke CD, Folks RD, Waldrop SM, Gurtler-Krawczynska E, Wittry MD, Garcia EV. Evaluation of left ventricular endocardial volumes and ejection fractions computed from gated perfusion SPECT with magnetic imaging: comparison of two methods. J Nucl Cardiol 2001; 8:645–651.

    Article  CAS  Google Scholar 

  21. Mochizuki T, Murase K, Tanaka H, Kondoh T, Hamamoto K, Tauxe WN. Assessment of left ventricular volume using ECG-gated SPECT with technetium-99m-MIBI and technetium-99m-tetrofosmin. J Nucl Med 1997; 38:53–57.

    CAS  PubMed  Google Scholar 

  22. Faber TL, Cooke CD, Folks RD, Vansant JP, Nichols KJ, DePuey EG, Pettigrew RI, Garcia EV. Left ventricular function and perfusion from gated SPECT perfusion images: an integrated method. J Nucl Med 1999; 40:650–659.

    CAS  PubMed  Google Scholar 

  23. Stollfuss JC, Haas F, Matsunari I, Neverve J, Nekolla S, Schneider-Eicke J, Schricke U, Ziegler S, Schwaiger M. Regional myocardial wall thickening and global ejection fraction in patients with low angiographic left ventricular ejection fraction assessed by visual and quantitative resting ECG-gated99mTc-tetrofosmin single-photon emission tomography and magnetic resonance imaging. Eur J Nucl Med 1998; 25:522–530.

    CAS  PubMed  Google Scholar 

  24. Chugh A, Ficaro EP, Moscucci M, Kritzman JN, Corbett JR. Quantification of left ventricular function by gated perfusion tomography: testing a new fully automatic algorithm [abstract]. J Nucl Cardiol 2001; 8:S19.

    Article  Google Scholar 

  25. Nakajima K, Higuchi T, Taki J, Kawano M, Tonami N. Accuracy of ventricular volume and ejection fraction measured by gated myocardial SPECT: comparison of 4 software programs J Nucl Med 2001; 42:1571–1578.

    CAS  Google Scholar 

  26. Lum DP, Coel MN. Comparison of automatic quantification software for the measurement of ventricular volume and ejection fraction in gated myocardial perfusion SPECT. Nucl Med Commun 2003; 24:259–266.

    Article  CAS  PubMed  Google Scholar 

  27. Dulce MC, Mostbeck GH, Friese KK, Caputo GR, Higgins CB. Quantification of the left ventricular volumes and function with cine MRI: comparison of geometric models with three-dimensional data. Radiology 1993; 188:371–376.

    CAS  PubMed  Google Scholar 

  28. Plein S, Bloomer TN, Ridgway JP, Jones TR, Bainbridge GJ, Sivananthan UM. Steady-state free precession magnetic resonance imaging of the heart: comparison with segmented k-space gradient echo imaging. J Magn Reson Imaging 2001; 14:230–236.

    Article  CAS  PubMed  Google Scholar 

  29. Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; 1:307–310.

    CAS  PubMed  Google Scholar 

  30. Barkhausen J, Ruehm SG, Goyen M, Buck T, Laub G, Debatin JF. MR evaluation of ventricular function: true fast imaging with steady-state precession versus fast low-angle shot cine MR imaging: feasibility study. Radiology 2001; 219:264–269.

    CAS  PubMed  Google Scholar 

  31. Pattynama PM, Lamb HJ, van der Velde EA, van der Wall EE, de Roos AA. Left ventricular measurements with cine and spin-echo MR imaging: a study of reproducibility with variance component analysis. Radiology 1993; 187:261–268.

    CAS  PubMed  Google Scholar 

  32. Kritzman JN, Ficaro EP, Corbett JR. Reproducibility of 3D-MSPECT for quantitative gated SPECT sestamibi perfusion analysis [abstract]. J Nucl Med 2000; 41:166P.

    Google Scholar 

  33. Ficaro EP, Lee BC, Kritzman JN, Corbett JR. Automatic realignment and centering of gated perfusion SPECT: effect on quantitative reproducibility [abstract]. J Nucl Med 2003; 44:198P.

    Google Scholar 

  34. Lee DS, Cheon GJ, Ahn JY, Chung JK, Lee MC. Reproducibility of assessment of myocardial function using gated 99Tc(m)-MIBI SPECT and quantitative software. Nucl Med Commun 2000; 12:1127–1134.

    Article  Google Scholar 

Download references

Acknowledgements

This project was funded by a grant from the IZKF BIOMAT (TV20/21, BMBF project No. 01 KS 9503/9), Germany.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Wolfgang M. Schaefer.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Lipke, C.S.A., Kühl, H.P., Nowak, B. et al. Validation of 4D-MSPECT and QGS for quantification of left ventricular volumes and ejection fraction from gated 99mTc-MIBI SPET: comparison with cardiac magnetic resonance imaging. Eur J Nucl Med Mol Imaging 31, 482–490 (2004). https://doi.org/10.1007/s00259-003-1411-y

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00259-003-1411-y

Keywords

Navigation