Skip to main content
Log in

Parathyroid 99mTc-sestamibi scintigraphy: dual-tracer subtraction is superior to double-phase washout

  • Original Article
  • Published:
European Journal of Nuclear Medicine and Molecular Imaging Aims and scope Submit manuscript

Abstract.

Technetium-99m sestamibi imaging for parathyroid adenoma localization has been performed using both dual-tracer subtraction and double-phase single-tracer washout techniques. The relative accuracy of these two techniques is uncertain. We have developed a modified imaging technique which combines both approaches and have directly compared them in a series of patients with surgically explored hyperparathyroidism. Initial injection of 99mTc-pertechnetate 50 MBq was followed by continuous dynamic imaging of the anterior neck for 30 min. 99mTc-sestamibi 1,000 MBq was injected intravenously at the midpoint of the acquisition. Delayed images were performed after 2 h. We blindly reviewed 88 consecutive cases of surgically explored hyperparathyroidism that had undergone preoperative scintigraphic localization with this procedure. Images were reformatted to display subtraction-only, early/delayed sestamibi-only and combined images. Scans were reviewed in random order. Of the 68 cases with solitary parathyroid adenoma, the sestamibi-only images gave correct localization in 49 (72%) while there was a statistically significant improvement in accuracy using the subtraction-only images (58 of 68, 85%, P=0.05) and the combined images (61 of 68, 90%, P=0.0015). Reader confidence was also greater with the subtraction-only and combined images than with the sestamibi-only images. Scan performance with parathyroid hyperplasia was less satisfactory. Although the largest gland was usually correctly identified, hyperplasia was difficult to distinguish from a solitary adenoma. Dual-tracer subtraction parathyroid imaging is superior to double-phase sestamibi-only imaging. The washout data may provide additional information in some cases, however, and an approach that combines both techniques may be optimal.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Electronic Publication

Rights and permissions

Reprints and permissions

About this article

Cite this article

Leslie, W.D., Dupont, J.O., Bybel, B. et al. Parathyroid 99mTc-sestamibi scintigraphy: dual-tracer subtraction is superior to double-phase washout. Eur J Nucl Med 29, 1566–1570 (2002). https://doi.org/10.1007/s00259-002-0944-9

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00259-002-0944-9

Navigation