Abstract
To evaluate the diagnostic value of technetium-99md,l-hexamethylpropylene amine oxime (HMPAO) labelled leucocytes in combination with a99mTc-methylene diphosphonate (MDP) bone scan in the detection of chronic osteomyelitis, we retrospectively reviewed 55 patients. Prior to the99mTc-d,I-HMPAO labelled leucocyte scan, all patients underwent a99mTc-MDP bone scan. The correct diagnosis was confirmed by long-term clinical follow-up (n=29) or by bacteriological cultures (n=26). We found an overall sensitivity of 94%, a specificity of 91% and an accuracy of 92% for99mTc-d,l-HMPAO labelled leucocyte scintigraphy in the diagnosis of chronic osteomyelitis. When the patients were divided into three groups according to the location of the infection, our study results showed a sensitivity and specificity for the central location (containing active bone marrow) of 94% and 100% respectively; for the peripheral location (hands and feet) both parameters were 100%, and for the middle location (all sites between the central and the peripheral location) the values were 92% and 81% respectively. Specificity and accuracy were significantly lower in the middle location than in the central and peripheral locations. The results of our study confirm that a99mTc-d,l-HMPAO labelled leucocyte scan in combination with an99mTc-MDP bone scan is a reliable way to diagnose chronic osteomyelitis, except for vertebral osteomyelitis.
Similar content being viewed by others
References
Waldvogel F, Medoff G, Swartz M. Osteomyelitis: A review of clinical features, therapeutic considerations and unusual aspects.N Engl J Med 1970; 282: 198–206.
Tumeh S, Aliabadi P, Weissman B, McNeil B. Disease activity in osteomyelitis: Role of radiography.Radiology 1987; 165: 781–784.
Schauwecker D. The scintigraphic diagnosis of osteomyelitis.AJR 1992; 158: 9–18.
Schauwecker D. Osteomyelitis: diagnosis with In-111-labeled leukocytes.Radiology 1989; 171: 141–146.
Skeikh W, Serafini A. Subacute and chronic bone infections: diagnosis using In-111, Ga-67 and Tc-99m MDP bone scintigraphy and radiography.Radiology 1985; 155: 501–506.
Mortelmans L, Malbrain S, Stuyck J, De Backker C, Heynen MJ, Boogaerts M, De Roo M, Verbruggen A. In vitro and in vivo evaluation of granulocyte labeling with99mTc-d,l-HMPAO.J Nucl Med 1989; 30: 2022–2028.
Ceretec, package insert. Amersham International Ltd, England, 1989.
Seabold J, Flickinger F, Kao S, Gleason T, Kahn D, Nepola J, Marsh J. Indium-111-leukocyte/technetium-99m-MDP bone and magnetic resonance imaging: difficulty of diagnosing osteomyelitis in patients with neuropathic osteoarthropathy.J Nucl Med 1990; 31: 549–556.
Tumeh S, Aliadabi P, Weissman B, McNeil B. Chronic osteomyelitis: bone and gallium scan patterns associated with active disease.Radiology 1986; 158: 685–688.
Merkel K, Fitzgerald R. Comparison of indium-labeled leukocyte imaging with technetium-gallium scanning in the diagnosis of low-grade musculoskeletal sepsis.J Bone Joint Surg Am 1985; 67-A: 465–476.
Wellman H, Schauwecker D, Capello W. Evaluation of metallic osseus implants with nuclear medicine.Semin Nucl Med 1988; 18: 126–136.
Vorne M, Soini I, Lantto T, Paakkinen. Technetium-99m HMPAO-labeled leukocytes in the detection of inflammatory lesions: comparison with gallium-67 citrate.J Nucl Med 1989; 30: 1332–1336.
Ivancevic V. Comparison of three-phase bone scan, three phase 99m-Tc-HM-PAO leukocyte scan and 67-gallium scan in chronic bone infection.Prog Clin Biol Res 1990; 355: 189–198.
Roddie M, Kelly D. Inflammation: Imaging with Tc-99m HMPAO-labeled leukocytes.Radiology 1988; 166: 767–772.
Peters M. The utility of [99mTc] HMPAO-leukocytes for imaging infection.Semin Nucl Med 1994; 24: 110–127.
Palestro J, Kim C, Swyer A, Vallabhajosula S, Goldschmith S. Radionuclide diagnosis of vertebral osteomyelitis: Indium-111-leukocyte and technetium-99m-methylene diphosphonate bone scintigraphy.J Nucl Med 1991; 32: 1861–1865.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Krznaric, E., De Roo, M., Verbruggen, A. et al. Chronic osteomyelitis: diagnosis with tech netium-99m-d,l-hexamethylpropylene amine oxime labelled leucocytes. Eur J Nucl Med 23, 792–797 (1996). https://doi.org/10.1007/BF00843708
Received:
Revised:
Issue Date:
DOI: https://doi.org/10.1007/BF00843708