Chronic osteomyelitis: diagnosis with tech netium-99m-d,l-hexamethylpropylene amine oxime labelled leucocytes

  • Original Article
  • Published:
European Journal of Nuclear Medicine Aims and scope Submit manuscript

Abstract

To evaluate the diagnostic value of technetium-99md,l-hexamethylpropylene amine oxime (HMPAO) labelled leucocytes in combination with a99mTc-methylene diphosphonate (MDP) bone scan in the detection of chronic osteomyelitis, we retrospectively reviewed 55 patients. Prior to the99mTc-d,I-HMPAO labelled leucocyte scan, all patients underwent a99mTc-MDP bone scan. The correct diagnosis was confirmed by long-term clinical follow-up (n=29) or by bacteriological cultures (n=26). We found an overall sensitivity of 94%, a specificity of 91% and an accuracy of 92% for99mTc-d,l-HMPAO labelled leucocyte scintigraphy in the diagnosis of chronic osteomyelitis. When the patients were divided into three groups according to the location of the infection, our study results showed a sensitivity and specificity for the central location (containing active bone marrow) of 94% and 100% respectively; for the peripheral location (hands and feet) both parameters were 100%, and for the middle location (all sites between the central and the peripheral location) the values were 92% and 81% respectively. Specificity and accuracy were significantly lower in the middle location than in the central and peripheral locations. The results of our study confirm that a99mTc-d,l-HMPAO labelled leucocyte scan in combination with an99mTc-MDP bone scan is a reliable way to diagnose chronic osteomyelitis, except for vertebral osteomyelitis.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Similar content being viewed by others

References

  1. Waldvogel F, Medoff G, Swartz M. Osteomyelitis: A review of clinical features, therapeutic considerations and unusual aspects.N Engl J Med 1970; 282: 198–206.

    Google Scholar 

  2. Tumeh S, Aliabadi P, Weissman B, McNeil B. Disease activity in osteomyelitis: Role of radiography.Radiology 1987; 165: 781–784.

    Google Scholar 

  3. Schauwecker D. The scintigraphic diagnosis of osteomyelitis.AJR 1992; 158: 9–18.

    Google Scholar 

  4. Schauwecker D. Osteomyelitis: diagnosis with In-111-labeled leukocytes.Radiology 1989; 171: 141–146.

    Google Scholar 

  5. Skeikh W, Serafini A. Subacute and chronic bone infections: diagnosis using In-111, Ga-67 and Tc-99m MDP bone scintigraphy and radiography.Radiology 1985; 155: 501–506.

    Google Scholar 

  6. Mortelmans L, Malbrain S, Stuyck J, De Backker C, Heynen MJ, Boogaerts M, De Roo M, Verbruggen A. In vitro and in vivo evaluation of granulocyte labeling with99mTc-d,l-HMPAO.J Nucl Med 1989; 30: 2022–2028.

    Google Scholar 

  7. Ceretec, package insert. Amersham International Ltd, England, 1989.

  8. Seabold J, Flickinger F, Kao S, Gleason T, Kahn D, Nepola J, Marsh J. Indium-111-leukocyte/technetium-99m-MDP bone and magnetic resonance imaging: difficulty of diagnosing osteomyelitis in patients with neuropathic osteoarthropathy.J Nucl Med 1990; 31: 549–556.

    Google Scholar 

  9. Tumeh S, Aliadabi P, Weissman B, McNeil B. Chronic osteomyelitis: bone and gallium scan patterns associated with active disease.Radiology 1986; 158: 685–688.

    Google Scholar 

  10. Merkel K, Fitzgerald R. Comparison of indium-labeled leukocyte imaging with technetium-gallium scanning in the diagnosis of low-grade musculoskeletal sepsis.J Bone Joint Surg Am 1985; 67-A: 465–476.

    Google Scholar 

  11. Wellman H, Schauwecker D, Capello W. Evaluation of metallic osseus implants with nuclear medicine.Semin Nucl Med 1988; 18: 126–136.

    Google Scholar 

  12. Vorne M, Soini I, Lantto T, Paakkinen. Technetium-99m HMPAO-labeled leukocytes in the detection of inflammatory lesions: comparison with gallium-67 citrate.J Nucl Med 1989; 30: 1332–1336.

    Google Scholar 

  13. Ivancevic V. Comparison of three-phase bone scan, three phase 99m-Tc-HM-PAO leukocyte scan and 67-gallium scan in chronic bone infection.Prog Clin Biol Res 1990; 355: 189–198.

    Google Scholar 

  14. Roddie M, Kelly D. Inflammation: Imaging with Tc-99m HMPAO-labeled leukocytes.Radiology 1988; 166: 767–772.

    Google Scholar 

  15. Peters M. The utility of [99mTc] HMPAO-leukocytes for imaging infection.Semin Nucl Med 1994; 24: 110–127.

    Google Scholar 

  16. Palestro J, Kim C, Swyer A, Vallabhajosula S, Goldschmith S. Radionuclide diagnosis of vertebral osteomyelitis: Indium-111-leukocyte and technetium-99m-methylene diphosphonate bone scintigraphy.J Nucl Med 1991; 32: 1861–1865.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Krznaric, E., De Roo, M., Verbruggen, A. et al. Chronic osteomyelitis: diagnosis with tech netium-99m-d,l-hexamethylpropylene amine oxime labelled leucocytes. Eur J Nucl Med 23, 792–797 (1996). https://doi.org/10.1007/BF00843708

Download citation

  • Received:

  • Revised:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00843708

Key words

Navigation