Abstract
The effect of different methods of stannous pyrophosphate (SnPYP) administration on a modified in vivo technique for labelling red blood cells (RBCs) with99mTc has been studied. Retention of99mTc in the bloodstream was measured and parallel in vitro RBC labelling experiments were performed. After administration of SnPYP or a mixture of SnPYP and heparin via the metal needles of intravenous cannulae, the mean 30-min retentions of99mTc were 96.8% (SD 8.6) and 95.3% (SD 12.4) respectively and the mean in vitro labelling efficiencies were 86.9% (SD 5.0) and 81.9% (SD 18.2) respectively. When the SnPYP was administered via teflon cannulae, the mean 30-min retention of99mTc was 40.0% (SD 16.7) and the in vitro labelling efficiency was 18.7% (SD 27.0). Reduced RBC labelling and rapid clearance of99mTc from the bloodstream were not explained by adsorption of stannous ion or pyrophosphate onto the teflon cannulae or retention of SnPYP in the cannulae. When labelling RBCs with99mTc it is important that SnPYP is not injected via a teflon cannula.
References
Brady TJ, Thrall JH, Walton JA, Brymer JF, Pitt B (1979) Exercise radionuclide ejection fraction: correlation with exercise contrast ventriculography. Radiology 132:703–705
Callahan RJ, Froelich JW, McKusick KA, Leppo J, Strauss HW (1982) A modified method for the in vivo labelling of red blood cells with99mTc. J Nucl Med 23:315–318
Hegge FN, Hamilton GW, Larson SM, Ritchie JL, Richards P (1978) Cardiac chamber imaging: a comparison of red blood cells labeled with99mTc in vitro and in vivo. J Nucl Med 19:129–134
Hladik WB, Nigg KK, Rhodes BA (1982) Drug-induced changes in the biologic distribution of radiopharmaceuticals. Semin Nucl Med 12:184–218
International Committee for Standardisation in Haematology (ICSH) (1973) Report: Panel on diagnostic applications of radioisotopes in haematology: Standard techniques for the measurement of red-cell and plasma volume. Br J Haematol 25:801–814
Pavel DG, Zimmer AM, Patterson VN (1977) In vivo labelling of red blood cells with99mTc: a new approach to blood pool visualization. J Nucl Med 18:305–308
Smith RK, Arterburn G (1980) Detection and localization of gastointestinal bleeding using99mTc-pyrophosphate in vivo labeled red blood cells. Clin Nucl Med 5:55–60
Standke R, Hor G, Maul F-D (1983) Fully automated sectorial equilibrium radionuclide ventriculography. Proposal of a method for routine use: Exercise and follow-up. Eur J Nucl Med 8:77–83
Thrall JH, Swanson DP (1979) Clinical comparison of cardiac blood pool visualization with technetium-99m red blood cells labeled in vivo with technetium-99m human serum albumin (letter to the editor, reply). J Nucl Med 20:1214–1215
Zanelli GD (1982) Effect of drugs used in the treatment of cardiovascular disease on the in vitro labelling of red blood cells with99mTc. Nucl Med Commun 3:155–161
Zimmer AM, Pavel DG (1977) Rapid miniaturized chromatographic quality control procedures for99mTc radiopharmaceuticals. J Nucl Med 18:1230–1233
Zimmer AM, Spies SM, Majewski W (1981) Effect of drugs on in vivo RBC labeling: A proposed mechanism of inhibition. Second International Symposium on Radiopharmacology, Chicago, Illinois
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Millar, A.M., Wathen, C.G. & Muir, A.L. Failure in labelling of red blood cells with99mTc: Interaction between intravenous cannulae and stannous pyrophosphate. Eur J Nucl Med 8, 502–504 (1983). https://doi.org/10.1007/BF00598911
Received:
Issue Date:
DOI: https://doi.org/10.1007/BF00598911