Abstract
This study investigated downscatter effects in cardiac single-photon emission tomographic studies with simultaneous thallium-201/technetium-99m acquisition, and evaluated a previously proposed subtraction technique for downscatter compensation. Ten studies were carried out with different defect sizes and locations and varying activity distributions using four energy windows: 70±10% keV, 140±10% keV, 100±10% KeV, and 103±16% keV. The subtraction technique used the 100 or 103-keV data to remove scattered99mTc counts from the 70-keV data. The size and contrast of infarcts in the dual-isotope 70-keV image were artificially decreased compared to those in the 140-keV image, caused by scattered99mTc counts that were comparable to the primary201T1 counts in the 70-keV window. The subtraction technique produced larger defects and more heterogeneous activity in the myocardial wall in dual-isotope 70-keV images compared to the corresponding201T1on-ly images. These artifacts were caused by the markedly different spatial distributions of scattered99mTc counts in the 100-keV (or 103-keV) window as compared with the 70-keV window. It is concluded that scattered99mTc photons may cause overestimation of ischemia and myocardial viability in simultaneous dual-isotope patient studies. The proposed subtraction technique was inaccurate and produced image artifacts. Adequate downscatter compensation methods must be developed before applying simultaneous201Tl/99mTc acquisition in clinical practice.
Similar content being viewed by others
Explore related subjects
Discover the latest articles and news from researchers in related subjects, suggested using machine learning.References
Berman DS, Kiat H, Friedman JD. Separate acquisition rest thallium-201 /stress technetium-99m sestamibi dual-isotope myocardial perfusion SPOT: a clinical validation study. J Am Coll Cardiol 1993; 22: 1455–1464.
Matzer L, Kiat H, Friedman J. Separate acquisition dual-isotope myocardial perfusion SPECT using pharmacological stress [abstract].J Am Call Cardiol 1992; 19: 127A.
Lowe VJ, Greer KL, Hanson MW, Jaszczak RJ, Coleman RE. Cardiac phantom evaluation of simultaneously acquired dualisotopoe rest thallium-201/stress-technetium-99m SPECT images.J Nucl Med 1993; 34: 1998–2006.
Kiat H, Germano G, Friedman J, et al. Comparative feasibility of separate or simultaneous rest thallium-201/stress technetium-99m-sestamibi dual-isotope myocardial perfusion SPECT. J Nucl Med 1994; 35: 542–548.
DePuey EG. Simultaneous thallium-201/technetium-99m dual-isotope cardiac SPECT: ready for prime time? [editorial]. J Nucl Med 1993; 34: 2006–2008.
Hademenos G, Weinstein H, McSherry B, Leppo J. An improved method for simultaneous dual isotope Tc-99m/T1-201 emission scintigraphy. IEEE Med Imag Conf Rec 1992; 1083-1085.
Yang D, Ragasa E, Gould L, et al. Radionuclide simultaneous dual-isotope stress myocardial perfusion study using the 'three window technique'. Clin Nucl Med 1993; 18: 852–857.
Moore SC, English RJ, Syravanh C, et al. Simultaneous Tc99m/T1-201 image using energy-based estimation of the spatial distributions of contaminant photons. IEEE Trans Nucl Sci 1995; 42: 1189–1195.
Wackers FJ, Berman DS, Maddahi J, et al. Technetium-99m hexakis 2-methoxyisobutyl isonitrile: human biodistribution, dosimetry, safety, and preliminary comparison to thallium-201 for myocardial perfusion imaging. J Nucl Med 1989; 30: 301–311.
Sorenson JA, Phelps ME. Physics in nuclear medicine. Orlando: Grune & Stratton; 1987: 367–368.
Berman DS, Kiat H, Van Train KF, Garcia E, Friedman J, Maddahi J. Tc-99m sestamibi imaging in the assessment of chronic coronary artery disease. Semin Nucl Med 1991; 21: 190–212.
Garcia E, Cooke CD, Van Train KF, et al. Technical aspects of myocardial SPECT imaging with Tc-99m sestamibi. Am J Cardiol 1990; 66: 23E-31E.
Germano G, Chua T, Kiat H, Areeda JS, Berman DS. A quantitative phantom analysis of artifacts due to hepatic activity in Tc-99m myocardial perfusion SPECT studies. J Nucl Med 1994;35:356–359.
Knesaurek K. A new dual-isotope convolution cross-talk correction method: a T1-201/Tc-99m SPECT cardiac phantom study. Med Phys 1994; 21: 1577–1583.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Cao, Z., Chen, C.C., Maunoury, C. et al. Phantom evaluation of simultaneous thallium-201/technetium-99m aquisition in single-photon emission tomography. Eur J Nucl Med 23, 1514–1520 (1996). https://doi.org/10.1007/BF01254477
Received:
Revised:
Issue Date:
DOI: https://doi.org/10.1007/BF01254477