TABLE 2

Results for 12 Simulations of RMS Error Between RS and RS with Poisson Noise Added for Different Processing Methods

Processing methodMeanSD
None57.8*14.3
FLT18.13.6
F121, 2 passes32.8*5.7
F121, 4 passes34.6*4.0
F121, 6 passes39.0*4.2
F121, 8 passes43.6*4.7
  • * Statistically different from FLT (P < 0.0001).

  • Data are for 6 methods and 2 kidneys. Number of coefficients for FLT was automatically determined, and number of F121 passes was varied from 2 to 8.