TABLE 2

Maximal Displacement in 3 Axes During Stress Acquisitions* Using Previous Frame or Frame 3 as Reference

Relative to previous frameRelative to frame 3
DirectionAdenosineRegadenosonPAdenosineRegadenosonP
Negative x−2.9 ± 1.8−2.3 ± 1.50.083−2.5 ± 1.9−2.9 ± 2.30.435
Negative y−3.1 ± 1.8−2.3 ± 1.50.024−4.8 ± 3.3−3.1 ± 2.00.012
Negative z−6.4 ± 3.7−4.9 ± 2.20.123−9.9 ± 5.3−7.1 ± 3.60.048
Positive x2.7 ± 1.41.8 ± 1.00.0072.2 ± 2.60.7 ± 1.50.063
Positive y2.6 ± 1.42.2 ± 1.70.0820.2 ± 2.30.7 ± 1.30.030
Positive z4.9 ± 2.53.7 ± 1.70.0340.4 ± 3.20.6 ± 2.30.229
  • * Frames 13–25 for adenosine and frames 15–25 for regadenoson.

  • Data are mean millimeters ± SD. Analysis for displacement relative to previous frame was done using Mann–Whitney tests. Analysis for displacement relative to frame 3 was done using independent-samples t tests.