TABLE 3

Cardiac Events and Gated SPECT MPI Findings in “False-Negative Scans”

False-negative MPI eventsGated SPECT MPI findingsTiming of injection
PCI 3 d after MPI: LCx, 70% midvessel stenosisNormal perfusion and functionCP resolved for >3 h
PCI 3 d after MPI: LCx, 90% stenosis; LAD, 20% stenosis; RCA, 50% stenosisNormal perfusion and functionCP resolved for 4 h
NSTEMI on same day as MPINormal perfusion and functionCP resolved for 5 h
  • LCx = left circumflex coronary artery; LAD = left anterior descending artery; RCA = right coronary artery; NSTEMI = non–ST-elevation myocardial infarction.