TABLE 4

Dose Range and Mean Doses to Fingers of Workers Involved in Handling Radiopharmaceuticals

Radiopharmaceuticals handledDose range (μSv/GBq)Mean ± SD finger dose (μSv/GBq)
GroupWorkersBase of fingersFingertipsBase of fingersFingertips
199mTc-Labeled compoundsRadiopharmacy staff8.2–28.558.5–99.817.0 ± 7.574.3 ± 19.8
Physicians10.8–21.634.7–83.813.4 ± 6.553.5 ± 21.9
2131IPhysicians61.9–106.5254.6–851.882.0 ± 13.8469.9 ± 267.0