Predicted RCP Values for All 81 Experiments Using Equation with Coefficients for Baker-Flex TLC and HPLC Methods
Run no. | Generator ingrowth time (h) | Eluate age (h) | Generator manufacturer | Activity (MBq) | Baker-Flex TLC RCP | HPLC RCP |
---|---|---|---|---|---|---|
1 | 24 | 0 | DuPont | 5,550 | 96.15 | 96.14 |
2 | 48 | 0 | DuPont | 5,550 | 96.23 | 96.27 |
3 | 72 | 0 | DuPont | 5,550 | 96.31 | 96.40 |
4 | 24 | 3 | DuPont | 5,550 | 96.92 | 96.69 |
5 | 48 | 3 | DuPont | 5,550 | 96.70 | 96.43 |
6 | 72 | 3 | DuPont | 5,550 | 96.49 | 96.17 |
7 | 24 | 6 | DuPont | 5,550 | 97.69 | 97.25 |
8 | 48 | 6 | DuPont | 5,550 | 97.18 | 96.60 |
9 | 72 | 6 | DuPont | 5,550 | 96.66 | 95.95 |
10 | 24 | 0 | DuPont | 21,275 | 94.66 | 94.34 |
11 | 48 | 0 | DuPont | 21,275 | 94.74 | 94.88 |
12 | 72 | 0 | DuPont | 21,275 | 94.82 | 95.41 |
13 | 24 | 3 | DuPont | 21,275 | 95.05 | 96.99 |
14 | 48 | 3 | DuPont | 21,275 | 94.83 | 95.04 |
15 | 72 | 3 | DuPont | 21,275 | 94.62 | 95.19 |
16 | 24 | 6 | DuPont | 21,275 | 95.43 | 95.44 |
17 | 48 | 6 | DuPont | 21,275 | 94.92 | 95.20 |
18 | 72 | 6 | DuPont | 21,275 | 94.41 | 94.96 |
19 | 24 | 0 | DuPont | 37,000 | 93.18 | 92.54 |
20 | 48 | 0 | DuPont | 37,000 | 93.26 | 93.48 |
21 | 72 | 0 | DuPont | 37,000 | 93.34 | 94.43 |
22 | 24 | 3 | DuPont | 37,000 | 93.18 | 93.09 |
23 | 48 | 3 | DuPont | 37,000 | 92.96 | 93.65 |
24 | 72 | 3 | DuPont | 37,000 | 92.75 | 94.20 |
25 | 24 | 6 | DuPont | 37,000 | 93.18 | 93.64 |
26 | 48 | 6 | DuPont | 37,000 | 92.67 | 93.81 |
27 | 72 | 6 | DuPont | 37,000 | 92.16 | 93.98 |
28 | 24 | 0 | Mallinckrodt | 5,550 | 93.88 | 94.43 |
29 | 48 | 0 | Mallinckrodt | 5,550 | 95.26 | 95.71 |
30 | 72 | 0 | Mallinckrodt | 5,550 | 96.64 | 96.98 |
31 | 24 | 3 | Mallinckrodt | 5,550 | 95.50 | 95.62 |
32 | 48 | 3 | Mallinckrodt | 5,550 | 96.58 | 96.51 |
33 | 72 | 3 | Mallinckrodt | 5,550 | 97.67 | 97.40 |
34 | 24 | 6 | Mallinckrodt | 5,550 | 97.11 | 96.82 |
35 | 48 | 6 | Mallinckrodt | 5,550 | 97.91 | 97.32 |
36 | 72 | 6 | Mallinckrodt | 5,550 | 98.69 | 97.82 |
37 | 24 | 0 | Mallinckrodt | 21,275 | 92.91 | 92.71 |
38 | 48 | 0 | Mallinckrodt | 21,275 | 94.28 | 94.40 |
39 | 72 | 0 | Mallinckrodt | 21,275 | 95.66 | 96.08 |
40 | 24 | 3 | Mallinckrodt | 21,275 | 94.14 | 93.90 |
41 | 48 | 3 | Mallinckrodt | 21,275 | 95.22 | 95.20 |
42 | 72 | 3 | Mallinckrodt | 21,275 | 96.31 | 96.50 |
43 | 24 | 6 | Mallinckrodt | 21,275 | 95.38 | 95.10 |
44 | 48 | 6 | Mallinckrodt | 21,275 | 96.16 | 96.01 |
45 | 72 | 6 | Mallinckrodt | 21,275 | 96.95 | 96.92 |
46 | 24 | 0 | Mallinckrodt | 37,000 | 91.93 | 90.99 |
47 | 48 | 0 | Mallinckrodt | 37,000 | 93.30 | 93.09 |
48 | 72 | 0 | Mallinckrodt | 37,000 | 94.68 | 95.18 |
49 | 24 | 3 | Mallinckrodt | 37,000 | 92.78 | 92.19 |
50 | 48 | 3 | Mallinckrodt | 37,000 | 93.86 | 93.89 |
51 | 72 | 3 | Mallinckrodt | 37,000 | 94.95 | 95.60 |
52 | 24 | 6 | Mallinckrodt | 37,000 | 93.63 | 93.39 |
53 | 48 | 6 | Mallinckrodt | 37,000 | 94.42 | 94.70 |
54 | 72 | 6 | Mallinckrodt | 37,000 | 95.21 | 96.02 |
55 | 24 | 0 | Medi-Physics | 5,550 | 95.96 | 96.51 |
56 | 48 | 0 | Medi-Physics | 5,550 | 96.51 | 96.56 |
57 | 72 | 0 | Medi-Physics | 5,550 | 97.07 | 96.62 |
58 | 24 | 3 | Medi-Physics | 5,550 | 96.56 | 96.71 |
59 | 48 | 3 | Medi-Physics | 5,550 | 96.82 | 96.38 |
60 | 72 | 3 | Medi-Physics | 5,550 | 97.08 | 96.05 |
61 | 24 | 6 | Medi-Physics | 5,550 | 97.16 | 96.92 |
62 | 48 | 6 | Medi-Physics | 5,550 | 97.12 | 96.20 |
63 | 72 | 6 | Medi-Physics | 5,550 | 97.09 | 95.48 |
64 | 24 | 0 | Medi-Physics | 21,275 | 96.25 | 96.28 |
65 | 48 | 0 | Medi-Physics | 21,275 | 96.81 | 96.74 |
66 | 72 | 0 | Medi-Physics | 21,275 | 97.37 | 97.21 |
67 | 24 | 3 | Medi-Physics | 21,275 | 96.47 | 96.48 |
68 | 48 | 3 | Medi-Physics | 21,275 | 96.73 | 96.56 |
69 | 72 | 3 | Medi-Physics | 21,275 | 97.00 | 96.64 |
70 | 24 | 6 | Medi-Physics | 21,275 | 96.69 | 96.69 |
71 | 48 | 6 | Medi-Physics | 21,275 | 96.66 | 96.38 |
72 | 72 | 6 | Medi-Physics | 21,275 | 96.63 | 96.07 |
73 | 24 | 0 | Medi-Physics | 37,000 | 96.55 | 96.67 |
74 | 48 | 0 | Medi-Physics | 37,000 | 97.11 | 96.05 |
75 | 72 | 0 | Medi-Physics | 37,000 | 97.67 | 96.92 |
76 | 24 | 3 | Medi-Physics | 37,000 | 96.39 | 97.79 |
77 | 48 | 3 | Medi-Physics | 37,000 | 96.65 | 96.25 |
78 | 72 | 3 | Medi-Physics | 37,000 | 96.91 | 96.74 |
79 | 24 | 6 | Medi-Physics | 37,000 | 96.22 | 97.22 |
80 | 48 | 6 | Medi-Physics | 37,000 | 96.19 | 96.46 |
81 | 72 | 6 | Medi-Physics | 37,000 | 96.16 | 96.56 |