PT - JOURNAL ARTICLE AU - Elahe Mahmoudi AU - Elahe Pirayesh AU - Mohammad Reza Deevband AU - Mahasti Amoui AU - Mohammadali Ghodsi Rad AU - Mehrdad Ghorbani Rad AU - Mahdi Ghorbani TI - Radiation Dose to Medical Staff in <sup>177</sup>Lu-PSMA-DKFZ-617 therapy And Estimation of Annual Dose AID - 10.2967/jnmt.121.263135 DP - 2021 Dec 01 TA - Journal of Nuclear Medicine Technology PG - jnmt.121.263135 4099 - http://tech.snmjournals.org/content/early/2021/12/06/jnmt.121.263135.short 4100 - http://tech.snmjournals.org/content/early/2021/12/06/jnmt.121.263135.full AB - Radioligand therapy applications for metastatic castration-resistant prostate cancer have been continuously rising in most nuclear medicine departments in Iran, but to our knowledge, no one has studied the doses of staff who perform treatment procedures. The current study aimed to determine the external radiation dose received by the staff of patients treated with 177Lu- prostate-specific membrane antigen therapy with and without a lead shield. This study used a dose ionization chamber to measure dose rates to the staff at various distances from patients and determined the average time spent by staff at these distances using an ionization chamber. Deep-dose equivalent to staff was obtained. The measured deep-dose equivalent to staff per patient was whitening the range of 1.8 to 5.2 mSv using a lead shield and 3.3 to 8.1 mSv without a lead shield. This study showed that a 2-mm lead shield markedly reduced the external dose to staff.It was indicated that the skill, accuracy, and speed of action of staff can directly affect their received dose.