TY - JOUR T1 - Performing an Additional Lateral Decubitus PET/CT Scan to Resolve a Respiratory Motion Artifact JF - Journal of Nuclear Medicine Technology JO - J. Nucl. Med. Technol. SP - 84 LP - 85 DO - 10.2967/jnmt.120.251975 VL - 49 IS - 1 AU - Roberto Rinaldi AU - Luca Camoni AU - Domenico Albano Y1 - 2021/03/01 UR - http://tech.snmjournals.org/content/49/1/84.abstract N2 - Respiratory motion artifacts may affect interpretation of whole-body 18F-FDG PET/CT scans, especially when lesions are localized between the liver and the lung. We report a case of a patient with breast cancer who underwent PET/CT after therapy and in whom focal 18F-FDG uptake of equivocal interpretation was observed between the liver and the pleura. A subsequent imaging acquisition of the right lateral decubitus showed that the lesion had a pleural location, thus improving the diagnostic accuracy of the PET/CT finding. ER -