PT - JOURNAL ARTICLE AU - Vines, Douglass AU - Denhartog, Paul AU - Kwan, David AU - Ichise, Masanori TI - Off-Site Determinations of Effective Renal Plasma Flow Using Technetium-99m-MAG3 and Single Blood Sampling DP - 1998 Mar 01 TA - Journal of Nuclear Medicine Technology PG - 23--25 VI - 26 IP - 1 4099 - http://tech.snmjournals.org/content/26/1/23.short 4100 - http://tech.snmjournals.org/content/26/1/23.full SO - J. Nucl. Med. Technol.1998 Mar 01; 26 AB - This study evaluated the feasibility of determining effective renal plasma flow (ERPF) at an off-site central laboratory by transferring blood samples from the on-site laboratory. Methods: Blood samples were obtained from 66 patients referred for renal imaging with 99mTc-MAG3. ERPF values were determined using the single blood sample method (BSM) at both on- and off-site laboratories. The ERPF values were classified clinically as normal or abnormal. Both the ERPF values and clinical classification were compared between on- and off-site laboratories. Results: The off-site ERPF overestimated those on-site by 2.8% (paired Student’s t-test p < 10−5). However, off-site ERPF values highly correlated with the values obtained onsite (r = 0.99; p < 10−5). In addition, the clinical classification for each patient determined at each site was identical. Conclusion: ERPF can be determined accurately off-site. This method should allow many nuclear medicine departments access to the ERPF determination by the BSM at a central off-site laboratory.