TY - JOUR T1 - Impact of Patient Motion on Myocardial Perfusion SPECT Diagnostic Integrity: Part 2 JF - Journal of Nuclear Medicine Technology JO - J. Nucl. Med. Technol. SP - 158 LP - 163 VL - 32 IS - 3 AU - Janelle M. Wheat AU - Geoffrey M. Currie Y1 - 2004/09/01 UR - http://tech.snmjournals.org/content/32/3/158.abstract N2 - Objective:Advances in 99mTc-based radiopharmaceuticals and multiple-detector gantries have the potential to increase the significance of patient motion on the diagnostic integrity of myocardial perfusion SPECT acquisitions. Methods:An experimental study was used to evaluate the effect of various patient motions on the diagnostic integrity of myocardial perfusion SPECT data using 522 motion simulations generated from a technically and diagnostically normal dataset. Results:Of studies with induced motion, 21.7% of simulated motion demonstrated motion-induced artifacts. Abrupt motion resulted in artifacts for 52.6% of studies, whereas bounce motion resulted in artifacts in 6.8% of studies. The locations where motion resulted in the most studies with artifacts were at 45° (36.1%) and 75° (32.4%). No statistical difference was demonstrated between single, dual-, and triple-head configurations. Conclusion:Combining these results with those of the clinical evaluation of incidence indicates that patient motion during 99mTc-based myocardial perfusion SPECT studies is a potential source of false-positive findings for coronary artery disease. There is a 7.1% probability that myocardial perfusion SPECT studies performed at the 3 sites investigated will contain a motion-induced artifact. Fully realized, this potential results in decreased test specificity and unfavorable cost and consequence outcomes. ER -