PT - JOURNAL ARTICLE AU - Steffel, Frank G. AU - Rao, Shyam A. TI - Rapid and Simple Methods for Labeling White Blood Cells and Platelets with Indium-111-Oxine DP - 1987 Jun 01 TA - Journal of Nuclear Medicine Technology PG - 61--65 VI - 15 IP - 2 4099 - http://tech.snmjournals.org/content/15/2/61.short 4100 - http://tech.snmjournals.org/content/15/2/61.full SO - J. Nucl. Med. Technol.1987 Jun 01; 15 AB - Simple procedures in a kit form for labeling white blood cells (WBCs) and platelets with commercially available indium-111 (111In)-oxine have been developed for the convenience of small community hospitals. The time required for the labeling procedure is less than 2 hr. The resulting scintigrams from the clinical studies in both WBCs and platelets showed that the 111In-labeled cells have a high degree of viability.