RT Journal Article SR Electronic T1 Correlation of Thyroid Uptake with Whole-Body Retention Measurements JF Journal of Nuclear Medicine Technology JO J. Nucl. Med. Technol. FD Society of Nuclear Medicine SP 72 OP 75 VO 3 IS 2 A1 Hodges, H.D. A1 Morris, A.C. A1 Gibbs, W.D. YR 1975 UL http://tech.snmjournals.org/content/3/2/72.abstract AB The use of conventional thyroid measurement is not practicable in a number of clinical situations. We investigated the correlation of 48-hr whole-body retention to thyroid uptake results at 4, 24, and 48 hr after administration. The 48-hr count gives the best results, confirmed in studies on 69 patients. Equations computed to fit our data show high levels of confidence with administered doses as low as 50 nCi. The technique can be used in infants, in pregnant women when there is a massive goiter, or in other clinical situations in which a conventional thyroid measurement is contraindicated or technically unsatisfactory.