PT - JOURNAL ARTICLE AU - K H Bohuslavizki AU - S Kröger AU - S Klutmann AU - M Geiss-Tönshoff AU - M Clausen TI - Pregnancy testing before high-dose radioiodine treatment: a case report. DP - 1999 Sep 01 TA - Journal of Nuclear Medicine Technology PG - 220--221 VI - 27 IP - 3 4099 - http://tech.snmjournals.org/content/27/3/220.short 4100 - http://tech.snmjournals.org/content/27/3/220.full SO - J. Nucl. Med. Technol.1999 Sep 01; 27 AB - This case emphasizes that negative urine pregnancy testing and a written declaration of the patient are not sufficient to safely exclude an early pregnancy. Serum pregnancy testing inherently has a diagnostic gap of about 1 wk following conception. We recommend sufficient contraception at least 1 mo before radioiodine treatment in women of childbearing age.