RT Journal Article SR Electronic T1 Practical Solid and Liquid Phase Markers for Studying Gastric Emptying in Man JF Journal of Nuclear Medicine Technology JO J. Nucl. Med. Technol. FD Society of Nuclear Medicine SP 11 OP 14 VO 13 IS 1 A1 George M. Thomforde A1 Manuel L. Brown A1 Juan-R. Malagelada YR 1985 UL http://tech.snmjournals.org/content/13/1/11.abstract AB This paper presents a method used to evaluate solid and liquid phase markers for radionuclide gastric emptying studies. We conducted in vitro and in vivo comparative experiments employing several radiolabeled markers. Among the solid phase markers tested, Tc-99m-sulfur colloid in vivo-labeled liver and I-131-fiber performed optimally. However, Tc-99m sulfur colloid in scrambled egg showed very acceptable performance and it is significantly easier to prepare. Among liquid phase markers, we found In-111-DTPA stabilized with 1% albumin to be a good agent and appropriate for dual isotope emptying studies.