PT - JOURNAL ARTICLE AU - Harpen, Michael D. AU - Dubuisson, Robert L. AU - Moates, Mariam G. AU - Stringfellow, Lesa R. TI - Quantitative Evaluation of Cardiac Volumes and Outputs: Technical Aspects DP - 1983 Sep 01 TA - Journal of Nuclear Medicine Technology PG - 107--110 VI - 11 IP - 3 4099 - http://tech.snmjournals.org/content/11/3/107.short 4100 - http://tech.snmjournals.org/content/11/3/107.full SO - J. Nucl. Med. Technol.1983 Sep 01; 11 AB - In addition to the ejection fractions and wall motion evaluations reported through conventional equilibrium gated blood pool scans, left ventricular volumes and cardiac output values may also be obtained. We describe a cardiac function study based on a model of the kinetics of a bolus of technetium-99m-labeled red cells through the left ventricle (1). Data acquisition requires only a slight modification of the conventional gated procedure. The method described has become a valuable adjunct to conventional radionuclide procedures for evaluation of left ventricular function at our institution.