PT - JOURNAL ARTICLE AU - Mock, Bruce H. AU - Conrad, Gary R. TI - Radiopharmaceutical Inventory and Dispensing System Based Upon a Hand-Held Computer DP - 1988 Mar 01 TA - Journal of Nuclear Medicine Technology PG - 21--24 VI - 16 IP - 1 4099 - http://tech.snmjournals.org/content/16/1/21.short 4100 - http://tech.snmjournals.org/content/16/1/21.full SO - J. Nucl. Med. Technol.1988 Mar 01; 16 AB - We have developed an inexpensive, hand-held system that performs all numeric calculations necessary to prepare, control, and dispense all routine radiopharmaceuticals. Our hand-held system is especially suitable for any nuclear medicine hot laboratory which seeks to improve its inventory and dispensing process, but cannot justify the expense of a personal computer-based or dose calibrator-integrated system. In addition, our system was designed to augment, rather than replace, the existing record-keeping methods unique to each hot-lab. This report describes the features of our inventory control and dispensing system and outlines the various algorithms used by our program.