RT Journal Article SR Electronic T1 A Multi-institutional In Vitro Evaluation of Commercial 99mTc Macroaggregated Albumin Kits JF Journal of Nuclear Medicine Technology JO J. Nucl. Med. Technol. FD Society of Nuclear Medicine SP 206 OP 209 VO 14 IS 4 A1 Callahan, Ronald J. A1 Swanson, Dennis P. A1 Petry, Neil A. A1 Beightol, Robert W. A1 Vaillancourt, Julienne A1 Dragotakes, Stephen C. YR 1986 UL http://tech.snmjournals.org/content/14/4/206.abstract AB Quality control testing of 99mTc macroaggregated albumin injection, U.S.P. (Tc-MAA) should include determination of radiochemical purity and particle size. We evaluated the variability in these parameters in vitro among products from five manufacturers of 99mTc-MAA kits. Radiochemical purity, as determined by supernatant activity determinations, varied from 0.5% to 16.0%. Although mean particle size was similar for all products tested, actual particle size distribution varied considerably among products tested.