PT - JOURNAL ARTICLE AU - Bauman, John M. AU - Landry, Alfred J. TI - Practical Platelet Labeling with Indium-111-Oxine DP - 1986 Mar 01 TA - Journal of Nuclear Medicine Technology PG - 15--17 VI - 14 IP - 1 4099 - http://tech.snmjournals.org/content/14/1/15.short 4100 - http://tech.snmjournals.org/content/14/1/15.full SO - J. Nucl. Med. Technol.1986 Mar 01; 14 AB - Interest in platelet scanning with IIIIndium-oxine labeled platelets is increasing. Although many methods are available, critical details of platelet labeling and quality control are often omitted. We describe a detailed technique that should be helpful to those unfamiliar with the special requirements of platelet labeling. The method requires ~ 90 min, uses common reagents, and yields a viable population of platelets with labeling efficiencies in excess of 95%.