RT Journal Article SR Electronic T1 Report on the PET/CT Image–Based Radiation Dosimetry of [18F]FDHT in Women, a Validated Imaging Agent with New Applications for Evaluation of Androgen Receptor Status in Women with Metastatic Breast Cancer JF Journal of Nuclear Medicine Technology JO J. Nucl. Med. Technol. FD Society of Nuclear Medicine SP 204 OP 210 DO 10.2967/jnmt.123.265623 VO 51 IS 3 A1 McCall, Keisha C. A1 Liu, Mofei A1 Cheng, Su-Chun A1 Abbott, Amanda A1 Dubey, Shipra A1 Young, Diane A1 Johnston, Mayzie A1 Van den Abbeele, Annick D. A1 Overmoyer, Beth A1 Jacene, Heather YR 2023 UL http://tech.snmjournals.org/content/51/3/204.abstract AB In a prospective clinical trial, [18F]fluoro-5α-dihydrotestosterone ([18F]FDHT), the radiolabeled analog of the androgen dihydrotestosterone, was used as a PET/CT imaging agent for in vivo assessment of metastatic androgen receptor–positive breast cancer in postmenopausal women. To our knowledge, this article presents the first report of PET/CT image–based radiation dosimetry of [18F]FDHT in women. Methods: [18F]FDHT PET/CT imaging was performed on a cohort of 11 women at baseline before the start of therapy and at 2 additional time points during selective androgen receptor modulator (SARM) therapy for androgen receptor–positive breast cancer. Volumes of interest (VOIs) were placed over the whole body and within source organs seen on the PET/CT images, and the time-integrated activity coefficients of [18F]FDHT were derived. The time-integrated activity coefficients for the urinary bladder were calculated using the dynamic urinary bladder model in OLINDA/EXM software, with biologic half-life for urinary excretion derived from VOI measurements of the whole body in postvoid PET/CT images. The time-integrated activity coefficients for all other organs were calculated from VOI measurements in the organs and the physical half-life of 18F. Organ dose and effective dose calculations were then performed using MIRDcalc, version 1.1. Results: At baseline before SARM therapy, the effective dose for [18F]FDHT in women was calculated as 0.020 ± 0.0005 mSv/MBq, and the urinary bladder was the organ at risk, with an average absorbed dose of 0.074 ± 0.011 mGy/MBq. Statistically significant decreases in liver SUV or uptake of [18F]FDHT were found at the 2 additional time points on SARM therapy (linear mixed model, P < 0.05). Likewise, absorbed dose to the liver also decreased by a small but statistically significant amount at the 2 additional time points (linear mixed model, P < 0.05). Neighboring abdominal organs of the gallbladder wall, stomach, pancreas, and adrenals also showed statistically significant decreases in absorbed dose (linear mixed model, P < 0.05). The urinary bladder wall remained the organ at risk at all time points. Absorbed dose to the urinary bladder wall did not show statistically significant changes from baseline at any of the time points (linear mixed model, P ≥ 0.05). Effective dose also did not show statistically significant changes from baseline (linear mixed model, P ≥ 0.05). Conclusion: Effective dose for [18F]FDHT in women before SARM therapy was calculated as 0.020 ± 0.0005 mSv/MBq. The urinary bladder wall was the organ at risk, with an absorbed dose of 0.074 ± 0.011 mGy/MBq.