RT Journal Article
SR Electronic
T1 18F-FDG PET/CT Versus 68Ga-PSMA-11 PET/CT in Evaluation of Distant Metastatic Disease in Recurrent Renal Cell Carcinoma
JF Journal of Nuclear Medicine Technology
JO J. Nucl. Med. Technol.
FD Society of Nuclear Medicine
SP 261
OP 262
DO 10.2967/jnmt.122.264014
VO 51
IS 3
A1 Parghane, Rahul V.
A1 Basu, Sandip
YR 2023
UL http://tech.snmjournals.org/content/51/3/261.abstract
AB Prostate-specific membrane antigen (PSMA) expression has been observed in the neovasculature of various malignancies. We present a case of metastatic renal cell carcinoma (RCC) with comparative 18F-FDG PET/CT and 68Ga-PSMA-11 imaging in which FDG PET/CT failed to detect metastatic thyroid disease and showed less 18F-FDG–concentrating lesions at other sites, whereas 68Ga-PSMA-11 PET/CT identified metastatic thyroid disease and demonstrated intensely 68Ga-PSMA-11–expressing distant metastatic lesions. 68Ga-PSMA-11 PET/CT may be considered a potentially useful imaging technique in RCC to detect metastasis and to guide the choice of specific treatments, such as PSMA-based radionuclide therapy in patients with recurrent metastatic RCC.