Skip to main content

Main menu

  • Home
  • Content
    • Current
      • JNMT Supplement
    • Ahead of print
    • Past Issues
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Rates
    • Journal Claims
    • Institutional and Non-member
  • Authors
    • Submit to JNMT
    • Information for Authors
    • Assignment of Copyright
    • AQARA Requirements
  • Info
    • Continuing Education
    • Reviewers
    • Permissions
    • Advertisers
    • Corporate & Special Sales
  • About
    • About Us
    • Editorial Board
    • Editorial Contact
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNMT
    • JNM
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine Technology
  • SNMMI
    • JNMT
    • JNM
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine Technology

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Rates
    • Journal Claims
    • Institutional and Non-member
  • Authors
    • Submit to JNMT
    • Information for Authors
    • Assignment of Copyright
    • AQARA Requirements
  • Info
    • Continuing Education
    • Reviewers
    • Permissions
    • Advertisers
    • Corporate & Special Sales
  • About
    • About Us
    • Editorial Board
    • Editorial Contact
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • Follow SNMMI on Twitter
  • Visit SNMMI on Facebook
  • Join SNMMI on LinkedIn
  • Subscribe to JNMT RSS feeds
Research ArticleImaging

Reexamining Compliance with Gastric Emptying Scintigraphy Guidelines: An Updated Analysis of the Intersocietal Accreditation Commission Database

Dawood Tafti, Mary Beth Farrell, M. Cory Dearborn and Kevin P. Banks
Journal of Nuclear Medicine Technology June 2023, jnmt.123.265496; DOI: https://doi.org/10.2967/jnmt.123.265496
Dawood Tafti
1Uniformed Services University of the Health Sciences, Bethesda, Maryland;
2Department of Radiology, San Antonio Uniformed Services Health Education Consortium, San Antonio, Texas; and
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Mary Beth Farrell
3Intersocietal Accreditation Commission, Ellicott City, Maryland
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
M. Cory Dearborn
2Department of Radiology, San Antonio Uniformed Services Health Education Consortium, San Antonio, Texas; and
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Kevin P. Banks
1Uniformed Services University of the Health Sciences, Bethesda, Maryland;
2Department of Radiology, San Antonio Uniformed Services Health Education Consortium, San Antonio, Texas; and
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • PDF
Loading

Visual Abstract

Figure
  • Download figure
  • Open in new tab
  • Download powerpoint

Abstract

Many variables can influence the results of gastric emptying scintigraphy (GES). A lack of standardization causes variability, limits comparisons, and decreases the credibility of the study. To increase standardization, in 2009 the Society of Nuclear Medicine and Molecular Imaging (SNMMI) published a guideline for a standardized, validated GES protocol for adults based on a 2008 consensus document. Laboratories must closely follow the consensus guideline to provide valid and standardized results as an incentive to achieve consistency in patient care. As part of the accreditation process, the Intersocietal Accreditation Commission (IAC) evaluates compliance with such guidelines. The rate of compliance with the SNMMI guideline was assessed in 2016 and showed a substantial degree of noncompliance. The aim of this study was to reassess compliance with the standardized protocol across the same cohort of laboratories, looking for changes and trends. Methods: The IAC nuclear/PET database was used to extract GES protocols from all laboratories applying for accreditation from 2018 to 2021, 5 y after the initial assessment. The number of labs was 118 (vs. 127 in the initial assessment). Each protocol was again evaluated for compliance with the methods described in the SNMMI guideline. The same 14 variables were assessed in a binary fashion: patient preparation (4 variables—types of medications withheld, withholding of these medication for 48 h, blood glucose ≤ 200 mg/dL, blood glucose recorded), meal (5 variables—use of consensus meal, nothing by mouth for 4 h or more, meal consumed within 10 min, documentation of percentage of meal consumed, meal labeled with 18.5–37 MBq [0.5–1.0 mCi]), acquisition (2 variables—anterior and posterior projections obtained, imaging each hour out to 4 h), and processing (3 variables—use of the geometric mean, decay correction of data, and measurement of percentage retention). Results: Protocols from the 118 labs demonstrated that compliance is improving in some key areas but remains suboptimal in others. Overall, labs were compliant with an average of 8 of the 14 variables, with a low of 1-variable compliance at 1 site, and only 4 sites compliant with all 14 variables. Nineteen sites met an 80% threshold for compliance (11+ variables). The variable with the highest compliance was the patient’s taking nothing by mouth for 4 h or more before the exam (97%). The variable with the lowest compliance was the recording of blood glucose values (3%). Notable areas of improvement include the use of the consensus meal, now 62% versus previously only 30% of labs. Greater compliance was also noted with measurement of retention percentages (instead of emptying percentages or half-times), with compliance by 65% of sites versus only 35% 5 y prior. Conclusion: Almost 13 y after the publication of the SNMMI GES guidelines, there is improving but still suboptimal protocol adherence among laboratories applying for IAC accreditation. Persistent variation in the performance of GES protocols may significantly affect patient management, as results may be unreliable. Using the standardized GES protocol permits interpretation of results in a consistent manner that allows interlaboratory comparisons and fosters acceptance of the test validity by referring clinicians.

  • gastric emptying scintigraphy
  • guidelines
  • accreditation
  • protocols
  • standardization

Footnotes

  • Published online Jun. 14, 2023.

View Full Text

This article requires a subscription to view the full text. If you have a subscription you may use the login form below to view the article. Access to this article can also be purchased.

SNMMI members

SNMMI Member Login

Login to the site using your SNMMI member credentials

Individuals

Non-Member Login

Login as an individual user

PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine Technology: 51 (3)
Journal of Nuclear Medicine Technology
Vol. 51, Issue 3
September 1, 2023
  • Table of Contents
  • About the Cover
  • Index by author
  • Complete Issue (PDF)
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine Technology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Reexamining Compliance with Gastric Emptying Scintigraphy Guidelines: An Updated Analysis of the Intersocietal Accreditation Commission Database
(Your Name) has sent you a message from Journal of Nuclear Medicine Technology
(Your Name) thought you would like to see the Journal of Nuclear Medicine Technology web site.
Citation Tools
Reexamining Compliance with Gastric Emptying Scintigraphy Guidelines: An Updated Analysis of the Intersocietal Accreditation Commission Database
Dawood Tafti, Mary Beth Farrell, M. Cory Dearborn, Kevin P. Banks
Journal of Nuclear Medicine Technology Jun 2023, jnmt.123.265496; DOI: 10.2967/jnmt.123.265496

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Reexamining Compliance with Gastric Emptying Scintigraphy Guidelines: An Updated Analysis of the Intersocietal Accreditation Commission Database
Dawood Tafti, Mary Beth Farrell, M. Cory Dearborn, Kevin P. Banks
Journal of Nuclear Medicine Technology Jun 2023, jnmt.123.265496; DOI: 10.2967/jnmt.123.265496
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
    • Visual Abstract
    • Abstract
    • MATERIALS AND METHODS
    • RESULTS
    • DISCUSSION
    • CONCLUSION
    • DISCLOSURE
    • Footnotes
    • REFERENCES
  • Figures & Data
  • Info & Metrics
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

  • Imaging Pathway of a Pediatric Patient with Succinate Dehydrogenase B-Deficient Paraganglioma
  • α-Labeling of J591, an Antibody Targeting Prostate-Specific Membrane Antigen: The Technique and Considerations from the First Dedicated Production Lab at an Academic Institution in the United States
  • Report on the PET/CT Image–Based Radiation Dosimetry of [18F]FDHT in Women, a Validated Imaging Agent with New Applications for Evaluation of Androgen Receptor Status in Women with Metastatic Breast Cancer
Show more Imaging

Similar Articles

Keywords

  • gastric emptying scintigraphy
  • guidelines
  • accreditation
  • protocols
  • standardization
SNMMI

© 2023 Journal of Nuclear Medicine Technology

Powered by HighWire