KRAS Mutation Detection with (2S,4R)-4-[18F]FGln for Noninvasive PDAC Diagnosis
S Liu, F Liu, X Hou, Q Zhang, Y Ren, H Zhu… - Molecular …, 2024 - ACS Publications
Pancreatic ductal adenocarcinoma (PDAC), which has a poor prognosis and nonspecific
symptoms and progresses rapidly, is the most common pancreatic cancer type. Inhibitors …
symptoms and progresses rapidly, is the most common pancreatic cancer type. Inhibitors …
An alternative method for determining the radiochemical purity of 99mTc-tetrofosmin
KC Amin, S Patel, A Doke, GB Saha - Journal of Nuclear Medicine …, 2011 - Soc Nuclear Med
The instant thin-layer chromatographic method of determining the radiochemical purity of
99mTc-tetrofosmin recommended by the manufacturer uses a mixture of acetone and …
99mTc-tetrofosmin recommended by the manufacturer uses a mixture of acetone and …
Validation of an alternative radiochemical purity method for [99mTc] pentetate ([99mTc] DTPA)
MC Borré, FC Tesán, NM Leonardi… - Applied Radiation and …, 2013 - Elsevier
Abstract [99m Tc] pentetate ([99m Tc] DTPA) is the most commonly used
radiopharmaceutical renography agent. The aim of this work was to validate an alternative …
radiopharmaceutical renography agent. The aim of this work was to validate an alternative …
Radio-UHPLC: A tool for rapidly determining the radiochemical purity of technetium-99m radiopharmaceuticals?
D Kryza, M Janier - Applied Radiation and Isotopes, 2013 - Elsevier
Determining the radiochemical purity (RCP) of technetium-99m (99mTc)
radiopharmaceuticals using the method described in the package insert is a time-consuming …
radiopharmaceuticals using the method described in the package insert is a time-consuming …
Evaluation of alternative rapid thin layer chromatography systems for quality control of technetium-99m radiopharmaceuticals
K Mang'era, D Wong, D Douglas, K Franz… - Applied Radiation and …, 2014 - Elsevier
Abstract Whatman 3MM™ and Tec-Control™ systems were evaluated as ITLC-SG
alternatives for 99mTc-radiopharmaceuticals. They compare well in accuracy and …
alternatives for 99mTc-radiopharmaceuticals. They compare well in accuracy and …
[HTML][HTML] Evaluation of Tetrofosmin Cold Kit Fractionation Using Alternative New Method of Quality Control for Testing Radiochemical Purity
N Bhatia, R Vatsa, VK Dhingra… - World Journal of …, 2022 - thieme-connect.com
Objective The aim of this study is to establish a method for the fractionation of tetrofosmin
cold kit under different storage conditions and to optimize an alternate chromatography …
cold kit under different storage conditions and to optimize an alternate chromatography …
Miniaturized radiochemical purity testing for 99mTc-HMPAO, 99mTc-HMDP, and 99mTc-tetrofosmin
A de la Fuente, R Zanca, R Boni… - Journal of Nuclear …, 2017 - Soc Nuclear Med
Quick methods are functional in clinical practice to ensure the fastest availability of
radiopharmaceuticals. For this purpose, we investigated the radiochemical purity of the …
radiopharmaceuticals. For this purpose, we investigated the radiochemical purity of the …
Validation of stationary phases in 111In-pentetreotide planar chromatography
E Moreno-Ortega, LM Mena-Bares… - Revista Española de …, 2013 - Elsevier
Introducción Tras el cese en la fabricación de ITLC-SG por Pall-Gelman, es necesaria la
validación de fases estacionarias alternativas. Objetivo Validar diferentes fases …
validación de fases estacionarias alternativas. Objetivo Validar diferentes fases …
Validación de fases estacionarias en la cromatografía planar de 111In-pentetreótida
E Moreno-Ortega, LM Mena-Bares… - Revista Española de …, 2013 - Elsevier
Introducción Tras el cese en la fabricación de ITLC-SG por Pall-Gelman, es necesaria la
validación de fases estacionarias alternativas. Objetivo Validar diferentes fases …
validación de fases estacionarias alternativas. Objetivo Validar diferentes fases …