Skip to main content

Main menu

  • Home
  • Content
    • Current
      • JNMT Supplement
    • Ahead of print
    • Past Issues
    • Continuing Education
    • JNMT Podcast
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Rates
    • Journal Claims
    • Institutional and Non-member
  • Authors
    • Submit to JNMT
    • Information for Authors
    • Assignment of Copyright
    • AQARA Requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
    • Corporate & Special Sales
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNMT
    • JNM
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine Technology
  • SNMMI
    • JNMT
    • JNM
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine Technology

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • Continuing Education
    • JNMT Podcast
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Rates
    • Journal Claims
    • Institutional and Non-member
  • Authors
    • Submit to JNMT
    • Information for Authors
    • Assignment of Copyright
    • AQARA Requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
    • Corporate & Special Sales
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • Watch or Listen to JNMT Podcast
  • Visit SNMMI on Facebook
  • Join SNMMI on LinkedIn
  • Follow SNMMI on Twitter
  • Subscribe to JNMT RSS feeds
Research ArticleImaging

A Practical Technique to Improve Visualization of Sentinel Nodes in the Axillary Region on Breast Lymphoscintigraphy: Medial Breast Traction by Patient

Savas Ozdemir, Lisa Corner, Toby Searcy, Swati Sharma and Smita Sharma
Journal of Nuclear Medicine Technology June 2022, 50 (2) 115-118; DOI: https://doi.org/10.2967/jnmt.121.262994
Savas Ozdemir
1Division of Nuclear Medicine and Molecular Imaging, Department of Radiology, University of Florida, Jacksonville, Florida;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Lisa Corner
1Division of Nuclear Medicine and Molecular Imaging, Department of Radiology, University of Florida, Jacksonville, Florida;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Toby Searcy
1Division of Nuclear Medicine and Molecular Imaging, Department of Radiology, University of Florida, Jacksonville, Florida;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Swati Sharma
2Department of Radiology, University of Florida, Jacksonville, Florida; and
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Smita Sharma
3Division of Women’s Imaging, Department of Radiology, University of Florida, Jacksonville, Florida
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • PDF
Loading

Visual Abstract

Figure
  • Download figure
  • Open in new tab
  • Download powerpoint

Abstract

Methods: A standard method of performing breast lymphoscintigraphy is to obtain anterior and lateral views after periareolar intradermal injection of a radiotracer. However, a sentinel lymph node may be obscured by the activity at the injection site, especially on anterior views. Also, breast tissue may cause attenuation to prevent sentinel node visualization. In cases in which a sentinel lymph node is visualized on one view but not the other view or a sentinel lymph node is either not visualized or inadequately visualized, we repeat anterior and lateral views during medial traction of the breast performed by the patient. Results: We have found the medial breast traction technique performed by the patient to be especially useful for identification of axillary sentinel nodes. Conclusion: Repeat images during medial traction of the breast by the patient is an effective technique to improve visualization of sentinel lymph nodes in the axillary region.

  • breast lymphoscintigraphy
  • lymphoscintigraphy techniques
  • sentinel node
  • medial traction

Breast lymphoscintigraphy is an established method in primary staging of patients with invasive breast cancer without a palpable or needle biopsy–proven lymph node. If a sentinel node biopsy is negative, complete axillary dissection is associated with an increased risk of short- and long-term complications such as lymphedema with no benefit in overall survival, disease-free survival, or regional control (1,2). Frequently, the procedure needs to be completed in a timely manner to comply with the operating room schedule. Depending on the location of the lymph node and positioning of the breast, activity at the injection site may obscure the sentinel lymph node. Repeat anterior and lateral planar views during medial traction of the breast by the patient is a simple and effective technique to improve visualization of lymph nodes. Demonstration of the sentinel node in 2 planes can help the surgeon determine its location.

MATERIALS AND METHODS

In our routine protocol, we administer approximately 15 MBq (0.5 mCi) of 99mTc-tilmanocept for same-day surgery, and approximately 35 MBq (1.0 mCi) for next-day surgery, at the 12-o’clock location of the periareolar breast intradermally using aseptic technique, followed by gentle massage to improve drainage of the radiotracer. At our center, we obtain anterior and lateral dynamic images immediately after injection of the tracer, followed by anterior and lateral planar images using a dual-head γ-camera. When the sentinel lymph node is visualized, transmission images are obtained using a 57Co flood source to demonstrate the body contour.

In cases in which, first, a sentinel lymph node is visualized on one view but not the other view (Figs. 1 and 2) or, second, a sentinel lymph node is either not visualized or inadequately visualized by 1 h after injection (Fig. 3), we repeat anterior and lateral views during medial traction of the breast performed by the patient (Fig. 4).

FIGURE 1.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 1.

(A and B) Anterior (A) and lateral (B) 99mTc-tilmanocept lymphoscintigraphy transmission images demonstrate focal area of increased uptake superior and posterior to injection site on lateral view. Focus of uptake inferolateral to injection site on anterior view is in lower position than uptake on lateral view in relation to injection site, suggesting it may not correspond to uptake on lateral view. (C and D) Repeat anterior (C) and lateral (D) images during medial breast traction by patient displaces superimposed injection site medially and clearly demonstrate sentinel node in axillary region on anterior view. Focal uptake inferolateral to injection site on anterior view is likely secondary to contamination.

FIGURE 2.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 2.

(A) Anterior 99mTc-tilmanocept lymphoscintigraphy image demonstrates focal areas of increased uptake superior to injection site. Sentinel node is not clearly identified. (B) Lateral image demonstrates lymph channels and sentinel node. (C and D) Repeat anterior (C) and lateral (D) images during medial breast traction demonstrate marked improvement of visualization of lymph channels and sentinel node on anterior view.

FIGURE 3.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 3.

(A and B) Anterior (A) and lateral (B) 99mTc-tilmanocept lymphoscintigraphy images demonstrate focal areas of increased uptake superior and posterior to injection site, which likely represent lymph channels and axillary sentinel node. (C and D) Repeat anterior (C) and lateral (D) images during medial breast traction demonstrate marked improvement of visualization of lymph channels and sentinel node on anterior and lateral views.

FIGURE 4.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 4.

Photograph shows medial breast traction during acquisition of anterior and lateral images.

RESULTS

We have found the medial breast traction technique performed by the patient to be especially useful.

DISCUSSION

Since the introduction of breast lymphoscintigraphy, various techniques have been used, including intratumor and peritumor injection, subcutaneous or intradermal injection to the quadrant of the breast where the tumor is located, or combinations of injection techniques (3,4). The periareolar injection technique is simple, with a high success rate in sentinel lymph node detection (5). The relatively high activity level at the injection site may obscure the sentinel node in the axillary region, especially on the anterior view.

Imaging in the standing (upright) position was demonstrated to improve visualization of the sentinel nodes (6,7). Image acquisition when the patient’s arm is 90° from the long axis of the patient to simulate the surgical position has been discussed. Because of the impracticality of obtaining lateral views, arm angles of between 135° and 180° have been suggested as a compromise (8). However, this is also not the native position of the surgery. Oblique camera views (45° from anterior views) with the arm in a 90° position may be obtained. A modified oblique view of the axilla when the arm was abducted and elevated using a foam wedge elevating the ipsilateral shoulder has been described and demonstrated improved identification of axillary sentinel nodes (9). However, this positioning is not practical for image acquisitions in 2 different views using a dual-head camera. Also, oblique images may be more difficult to interpret (8). Image acquisitions in a prone position with the breast hanging using a special pad with cutouts to move the injection site away from the axilla has been described. This method requires an additional position and maneuvering of the patient and is different from the position during surgery (10). Breast displacement maneuvers have been suggested (8,10,11). These maneuvers include taping the breast or using a breast holder. In our practice, we have found a medial breast traction technique performed by the patient to be especially useful. SPECT/CT is an excellent modality for evaluation of the sentinel node location. Unfortunately, it has limited use because of its high cost and the additional radiation dose to the patient from the CT portion of the examination. The total effective dose from the low-dose CT portion of SPECT/CT is approximately 3 mSv, as compared with the radiation dose from a 57Co flood source, which is on the order of microsieverts (12).

We use a 57Co flood source for transmission images. A 153Gd flood source, which has primary photon emissions significantly below the 99mTc emission window, has been suggested. This method may improve image quality because of the reduced crosstalk and increase signal-to-noise ratio (13). However, the images need to be acquired in a separate window and fused, requiring additional time for postprocessing.

CONCLUSION

Breast lymphoscintigraphy requires coordination with the referring surgeon, the patient preadmission staff, and the operating room staff, especially for same-day procedures. It is important to complete studies in a timely manner. Necessary information needs to be provided to the surgeon. Therefore, patient scheduling, injection technique, and imaging protocol need to be tailored to meet the demand. Repeat imaging during medial breast traction by the patient is a fast, inexpensive, and practical technique to improve visualization of sentinel lymph nodes.

DISCLOSURE

No potential conflict of interest relevant to this article was reported.

KEY POINTS

QUESTION: Can medial breast traction by the patient improve visualization of sentinel lymph nodes in the axillary region?

PERTINENT FINDINGS: Repeat images during medial traction of the breast by the patient is an effective technique to improve visualization of the sentinel lymph nodes.

IMPLICATIONS FOR PATIENT CARE: Improved visualization of the sentinel lymph node can help the surgeon determine its location during surgery.

Footnotes

  • Published online Nov. 8, 2021.

REFERENCES

  1. 1.↵
    1. Krag DN,
    2. Anderson SJ,
    3. Julian TB,
    4. et al
    . Sentinel-lymph-node resection compared with conventional axillary-lymph-node dissection in clinically node-negative patients with breast cancer: overall survival findings from the NSABP B-32 randomised phase 3 trial. Lancet Oncol. 2010;11:927–933.
    OpenUrlCrossRefPubMed
  2. 2.↵
    1. Newman LA
    . Lymphatic mapping and sentinel lymph node biopsy in breast cancer patients: a comprehensive review of variations in performance and technique. J Am Coll Surg. 2004;199:804–816.
    OpenUrlCrossRefPubMed
  3. 3.↵
    1. Young MA
    . Lymphoscintigraphic mapping in melanoma and breast cancer. J Nucl Med Technol. 2020;48:311–314.
    OpenUrlAbstract/FREE Full Text
  4. 4.↵
    1. Thomas KS,
    2. Williams J
    . Lymphoscintigraphy: breast and melanoma. J Nucl Med Technol. 2020;48:315–316.
    OpenUrlFREE Full Text
  5. 5.↵
    1. Shimazu K,
    2. Tamaki Y,
    3. Taguchi T,
    4. Takamura Y,
    5. Noguchi S
    . Comparison between periareolar and peritumoral injection of radiotracer for sentinel lymph node biopsy in patients with breast cancer. Surgery. 2002;131:277–286.
    OpenUrlCrossRefPubMed
  6. 6.↵
    1. Anagnostou C,
    2. Baiocco C,
    3. Arnulfo A,
    4. Liberatore M,
    5. Baccheschi AM,
    6. Inglese E
    . The value of imaging in standing position in preoperative breast lymphoscintigraphy. Clin Nucl Med. 2011;36:683–688.
    OpenUrlCrossRefPubMed
  7. 7.↵
    1. Pierini A,
    2. Dworkin HJ
    . Is the upright position more sensitive than the supine position in breast cancer sentinel node lymphoscintigraphy? Clin Nucl Med. 2001;26:823–825.
    OpenUrlCrossRefPubMed
  8. 8.↵
    1. Krynyckyi BR,
    2. Miner M,
    3. Ragonese JM,
    4. Firestone M,
    5. Kim CK,
    6. Machac J
    . Technical aspects of performing lymphoscintigraphy: optimization of methods used to obtain images. Clin Nucl Med. 2000;25:978–985.
    OpenUrlCrossRefPubMed
  9. 9.↵
    1. Haigh PI,
    2. Hansen NM,
    3. Giuliano AE,
    4. Edwards GK,
    5. Ye W,
    6. Glass EC
    . Factors affecting sentinel node localization during preoperative breast lymphoscintigraphy. J Nucl Med. 2000;41:1682–1688.
    OpenUrlAbstract/FREE Full Text
  10. 10.↵
    1. Krynyckyi BR,
    2. Kim CK,
    3. Goyenechea MR,
    4. Chan PT,
    5. Zhang ZY,
    6. Machac J
    . Clinical breast lymphoscintigraphy: optimal techniques for performing studies, image atlas, and analysis of images. Radiographics. 2004;24:121–145.
    OpenUrlCrossRefPubMed
  11. 11.↵
    1. Giammarile F,
    2. Alazraki N,
    3. Aarsvold JN,
    4. et al
    . The EANM and SNMMI practice guideline for lymphoscintigraphy and sentinel node localization in breast cancer. Eur J Nucl Med Mol Imaging. 2013;40:1932–1947.
    OpenUrlCrossRefPubMed
  12. 12.↵
    1. Law M,
    2. Ma WH,
    3. Leung R,
    4. et al
    . Evaluation of patient effective dose from sentinel lymph node lymphoscintigraphy in breast cancer: a phantom study with SPECT/CT and ICRP-103 recommendations. Eur J Radiol. 2012;81:e717–720.
    OpenUrlCrossRefPubMed
  13. 13.↵
    1. DiFilippo FP,
    2. Brunken RC,
    3. Neumann DR
    . Transmission imaging in lymphoscintigraphy with a 153Gd flood source. J Nucl Med Technol. 2015;43:253–260.
    OpenUrlAbstract/FREE Full Text
  • Received for publication August 4, 2021.
  • Revision received September 21, 2021.
PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine Technology: 50 (2)
Journal of Nuclear Medicine Technology
Vol. 50, Issue 2
June 1, 2022
  • Table of Contents
  • About the Cover
  • Index by author
  • Complete Issue (PDF)
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine Technology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
A Practical Technique to Improve Visualization of Sentinel Nodes in the Axillary Region on Breast Lymphoscintigraphy: Medial Breast Traction by Patient
(Your Name) has sent you a message from Journal of Nuclear Medicine Technology
(Your Name) thought you would like to see the Journal of Nuclear Medicine Technology web site.
Citation Tools
A Practical Technique to Improve Visualization of Sentinel Nodes in the Axillary Region on Breast Lymphoscintigraphy: Medial Breast Traction by Patient
Savas Ozdemir, Lisa Corner, Toby Searcy, Swati Sharma, Smita Sharma
Journal of Nuclear Medicine Technology Jun 2022, 50 (2) 115-118; DOI: 10.2967/jnmt.121.262994

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
A Practical Technique to Improve Visualization of Sentinel Nodes in the Axillary Region on Breast Lymphoscintigraphy: Medial Breast Traction by Patient
Savas Ozdemir, Lisa Corner, Toby Searcy, Swati Sharma, Smita Sharma
Journal of Nuclear Medicine Technology Jun 2022, 50 (2) 115-118; DOI: 10.2967/jnmt.121.262994
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
    • Visual Abstract
    • Abstract
    • MATERIALS AND METHODS
    • RESULTS
    • DISCUSSION
    • CONCLUSION
    • DISCLOSURE
    • Footnotes
    • REFERENCES
  • Figures & Data
  • Info & Metrics
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

  • Early 10-Minute Postinjection [18F]F-FAPI-42 uEXPLORER Total-Body PET/CT Scanning Protocol for Staging Lung Cancer Using HYPER Iterative Reconstruction
  • Single- Versus Dual-Time-Point Imaging for Transthyretin Cardiac Amyloid Using 99mTc-Pyrophosphate
  • Does Arthrography Improve Accuracy of SPECT/CT for Diagnosis of Aseptic Loosening in Patients with Painful Knee Arthroplasty: A Systematic Review and Metaanalysis
Show more Imaging

Similar Articles

Keywords

  • breast lymphoscintigraphy
  • lymphoscintigraphy techniques
  • sentinel node
  • medial traction
SNMMI

© 2025 SNMMI

Powered by HighWire