Skip to main content
  • Main menu
  • User menu
  • Search
  • English ▼
    • English
    • Afrikaans
    • Albanian
    • Amharic
    • Arabic
    • Armenian
    • Azerbaijani
    • Basque
    • Belarusian
    • Bengali
    • Bosnian
    • Bulgarian
    • Catalan
    • Cebuano
    • Chichewa
    • Chinese (Simplified)
    • Chinese (Traditional)
    • Corsican
    • Croatian
    • Czech
    • Danish
    • Dutch
    • Esperanto
    • Estonian
    • Filipino
    • Finnish
    • French
    • Frisian
    • Galician
    • Georgian
    • German
    • Greek
    • Gujarati
    • Haitian Creole
    • Hausa
    • Hawaiian
    • Hebrew
    • Hindi
    • Hmong
    • Hungarian
    • Icelandic
    • Igbo
    • Indonesian
    • Irish
    • Italian
    • Japanese
    • Javanese
    • Kannada
    • Kazakh
    • Khmer
    • Korean
    • Kurdish (Kurmanji)
    • Kyrgyz
    • Lao
    • Latin
    • Latvian
    • Lithuanian
    • Luxembourgish
    • Macedonian
    • Malagasy
    • Malay
    • Malayalam
    • Maltese
    • Maori
    • Marathi
    • Mongolian
    • Myanmar (Burmese)
    • Nepali
    • Norwegian
    • Pashto
    • Persian
    • Polish
    • Portuguese
    • Punjabi
    • Romanian
    • Russian
    • Samoan
    • Scottish Gaelic
    • Serbian
    • Sesotho
    • Shona
    • Sindhi
    • Sinhala
    • Slovak
    • Slovenian
    • Somali
    • Spanish
    • Sudanese
    • Swahili
    • Swedish
    • Tajik
    • Tamil
    • Telugu
    • Thai
    • Turkish
    • Ukrainian
    • Urdu
    • Uzbek
    • Vietnamese
    • Welsh
    • Xhosa
    • Yiddish
    • Yoruba
    • Zulu

Main menu

  • Home
  • Content
    • Current
      • JNMT Supplement
    • Ahead of print
    • Past Issues
    • Continuing Education
    • JNMT Podcast
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Rates
    • Journal Claims
    • Institutional and Non-member
  • Authors
    • Submit to JNMT
    • Information for Authors
    • Assignment of Copyright
    • AQARA Requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
    • Corporate & Special Sales
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNMT
    • JNM
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine Technology
  • SNMMI
    • JNMT
    • JNM
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine Technology

Advanced Search

English ▼
  • English
  • Afrikaans
  • Albanian
  • Amharic
  • Arabic
  • Armenian
  • Azerbaijani
  • Basque
  • Belarusian
  • Bengali
  • Bosnian
  • Bulgarian
  • Catalan
  • Cebuano
  • Chichewa
  • Chinese (Simplified)
  • Chinese (Traditional)
  • Corsican
  • Croatian
  • Czech
  • Danish
  • Dutch
  • Esperanto
  • Estonian
  • Filipino
  • Finnish
  • French
  • Frisian
  • Galician
  • Georgian
  • German
  • Greek
  • Gujarati
  • Haitian Creole
  • Hausa
  • Hawaiian
  • Hebrew
  • Hindi
  • Hmong
  • Hungarian
  • Icelandic
  • Igbo
  • Indonesian
  • Irish
  • Italian
  • Japanese
  • Javanese
  • Kannada
  • Kazakh
  • Khmer
  • Korean
  • Kurdish (Kurmanji)
  • Kyrgyz
  • Lao
  • Latin
  • Latvian
  • Lithuanian
  • Luxembourgish
  • Macedonian
  • Malagasy
  • Malay
  • Malayalam
  • Maltese
  • Maori
  • Marathi
  • Mongolian
  • Myanmar (Burmese)
  • Nepali
  • Norwegian
  • Pashto
  • Persian
  • Polish
  • Portuguese
  • Punjabi
  • Romanian
  • Russian
  • Samoan
  • Scottish Gaelic
  • Serbian
  • Sesotho
  • Shona
  • Sindhi
  • Sinhala
  • Slovak
  • Slovenian
  • Somali
  • Spanish
  • Sudanese
  • Swahili
  • Swedish
  • Tajik
  • Tamil
  • Telugu
  • Thai
  • Turkish
  • Ukrainian
  • Urdu
  • Uzbek
  • Vietnamese
  • Welsh
  • Xhosa
  • Yiddish
  • Yoruba
  • Zulu
  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • Continuing Education
    • JNMT Podcast
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Rates
    • Journal Claims
    • Institutional and Non-member
  • Authors
    • Submit to JNMT
    • Information for Authors
    • Assignment of Copyright
    • AQARA Requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
    • Corporate & Special Sales
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • Watch or Listen to JNMT Podcast
  • Visit SNMMI on Facebook
  • Join SNMMI on LinkedIn
  • Follow SNMMI on Twitter
  • Subscribe to JNMT RSS feeds
Review ArticleContinuing Education

The Importance of Measurement for Quality Improvement: Submaximal Cardiac Stress Testing

Mary Beth Farrell
Journal of Nuclear Medicine Technology June 2020, 48 (2) 122-125; DOI: https://doi.org/10.2967/jnmt.120.244525
Mary Beth Farrell
Intersocietal Accreditation Commission, Ellicott City, Maryland
CNMT, FSNMMI-TS
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • PDF
Loading

Abstract

One of the most effective techniques to improve quality is to measure quality. The aim of this article is to defend the importance of quality measurement in nuclear medicine using the long-standing problem of submaximal exercise stress testing. Numerous evidence-based guidelines and research studies establish the importance of maximal stress testing for myocardial perfusion imaging. The 3 cutoffs for adequate cardiac stress that must be met are expenditure of 5 metabolic equivalents of energy, production of symptoms (e.g., fatigue or shortness of breath), and attainment of 85% of the maximum predicted heart rate. Measurement and evaluation of these 3 criteria along with several other metrics can help to validate one aspect of laboratory quality related to myocardial perfusion imaging accuracy.

  • exercise stress testing
  • submaximal stress
  • quality improvement
  • measurement
  • guideline adherence

The Institute of Medicine defines quality as “the degree to which health services for individuals and populations increase the likelihood of desired health outcomes and are consistent with current professional knowledge” (1). Key to this definition is a comprehensive understanding of 2 phrases: “health outcomes” and “consistent with professional knowledge.” Health outcomes, otherwise referred to as patient outcomes, as defined by the World Health Organization are “a change in the health of an individual, group of people, or population that is attributable to an intervention or series of interventions” (2). Professional knowledge, otherwise referred to as evidence-based medicine, is the careful, precise, judicious, and sensible use of current knowledge and evidence when making decisions on the care of a patient (3). It is important to note that evidence-based medicine values use of the soundest information available and skillfully combines a physician’s clinical experience and expertise with a patient’s desires.

One of the most effective ways to improve health outcomes is through the application of professional, evidence-based guidelines (4). Evidence-based imaging guidelines provide concise instructions on how to perform a procedure, thus ensuring standardization and improving quality (5). However, the question arises, “How do you know you are improving quality?” One way to assess quality and to safeguard improvement is through measurement. Laboratories must select appropriate metrics and apply the correct knowledge base to improve quality.

The aim of this article is to defend the importance of measurement in improving quality. This article will describe a long-standing quality issue in nuclear cardiology that is recently getting renewed attention: submaximal stress testing. The paper will describe that problem, explain the evidence-based guidelines related to the problem, and suggest metrics to quantify and correct the problem.

IMPORTANCE OF MEASURING QUALITY

There is a plethora of axioms and reasons to support the importance of measurement in improving quality. Peter Drucker, a pioneer in quality, is credited with stating, “you can’t manage what you can’t measure” (6). By this, Drucker meant you cannot determine whether you are successful unless you first define success and track it. When success is bound by a metric, progress can be quantified, and actions can be adjusted to produce the desired outcome. A quote from H. James Harrington, another guru of quality, is more prescriptive than Drucker. Harrington is credited with stating, “Measurement is the first step that leads to control and eventually to improvement. If you can’t measure something, you can’t understand it. If you can’t understand it, you can’t control it. If you can’t control it, you can’t improve it” (7).

One practical reason for measuring is that it increases confidence in decision-making (8). For example, baseball coaches use players’ batting averages to determine where to put them in the line-up. Measurement helps an individual know what is going on, or the status of things. Teachers use the results of tests to assess how well a student comprehends the material. Measurement monitors, or keeps tabs, and is an indicator of change—whether that change is an improvement or a deterioration. If decline is noted, measurements highlight the need for improvement. Metrics provide a framework to keep people focused on what is most important. It allows them to set goals and then evaluate progress.

Through measurement, a view of the entire system can be obtained, providing a more comprehensive understanding of system function as opposed to anecdotal occurrences. Systematic assessments as opposed to haphazard, random efforts to evaluate and enhance quality produce better long-term results (9). Deliberate data collection and analyses produce more consequential system transformation than do knee-jerk reactions and policing actions. By evaluating systems, long-term “cures” are obtainable as opposed to just treating the system’s “symptoms.”

Perhaps the most definitive reason for measuring quality in health care was provided by the Agency for Healthcare Research and Quality. In its 2012 National Healthcare Quality Report, it noted that “patients receive the proper diagnosis and care only about 55% of the time” (10). Although this figure represents the continuum of patients and diagnoses, it is appropriate for diagnostic medicine because clinicians derive most diagnoses based on the results of an imaging procedure or clinical laboratory test.

QUALITY IN ADVANCED DIAGNOSTIC IMAGING

Hendee et al. estimated that between 20% and 50% of advanced diagnostic imaging tests (i.e., nuclear medicine, CT, and MRI) do not provide results improving patient outcomes (11). There are many reasons why a diagnostic imaging test may fail to provide meaningful information. For example, the referring physician may not have ordered the correct scan to answer the clinical question. Referring physicians must order the most appropriate test from the profusion of available imaging options, with new tests and clinical indications continually emerging. Suboptimal imaging findings can occur if the patient was not adequately prepared for the test or the test is performed incorrectly. For example, if a patient does not fast before a cardiac PET scan, the heart will fail to accumulate the radiotracer and the images will be of poor quality (12).

One diagnostic accuracy problem in nuclear cardiology has received recent public attention. A study published in JACC: Cardiovascular Imaging and picked up by the media in April 2019 found considerable variation in the performance of stress testing at U.S. Department of Veterans Affairs hospitals (13). At issue was the diagnostic accuracy of myocardial perfusion imaging due to submaximal cardiac stress testing.

SUBMAXIMAL STRESS TESTING AND EVIDENCE-BASED GUIDELINES

The goal of stress myocardial perfusion imaging is to provoke myocardial ischemia (decreased blood flow) to a region of the heart at risk of infarction. In essence, the objective is to diagnose coronary artery disease by comparing the blood flow to the heart muscle during stress and resting conditions using radioactive tracers and nuclear medicine scanners (14). For the test to be accurate, patients must adequately exert themselves during an exercise treadmill test to produce ischemia. If a patient cannot exercise to sufficient levels, the test can be performed using pharmacologic agents to simulate exercise. The problem is that in many nuclear cardiology stress laboratories, the radioactive tracer is being injected too soon or before the patient has reached the ischemic threshold. Bluntly stated, many facilities inject the moment the patient reaches 85% of the maximum predicted heart rate. The result is a false-negative test—meaning the imaging results do not show ischemia, incorrectly indicating the patient’s coronary arteries are healthy when in fact they may contain a blockage. Without an adequate cardiac stress test, there is no way to determine whether the patient is or is not at risk of infarction.

A substantial number of clinical research studies have evaluated and determined an adequate level of exercise in most adults to produce ischemia. There are 3 cutoffs for adequate cardiac stress that the patient must meet: the patient must expend 5 metabolic equivalents (METs) of energy (a workload of about 6 min using the standard Bruce protocol for the treadmill), indicating moderate exercise sufficient to provoke ischemia; the heart rate must reach a level higher than 85% of the maximum predicted heart rate based on age (maximum predicted heart rate = 220 – age); and the patient must have symptoms such as fatigue, shortness of breath, chest pain, or electrocardiogram changes indicative of ischemia (15,16). Basically, the patient must be markedly fatigued. The published evidence-based, clinical guidelines from various professional imaging societies mandate that the patient must meet these 3 exercise requirements or undergo a pharmacologic stress test.

SUBMAXIMAL STRESS QUALITY IMPROVEMENT

To assess current laboratory adherence to the evidence-based guidelines for stress myocardial perfusion imaging and set baseline levels, the following metrics are suggested: patient identification number, sex, age, maximum predicted heart rate, exercise protocol, METs achieved, total exercise time, peak heart rate, peak systolic blood pressure, rate–pressure product, symptoms, electrocardiogram findings, and myocardial perfusion imaging findings and whether the patient performed maximal-stress exertion or required a pharmacologic stress test (Fig. 1).

FIGURE 1.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 1.

Sample data collection form with critical metrics to ascertain adequacy of cardiac stress testing before myocardial perfusion imaging. The most critical variables are percentage of maximum predicted heart rate, METs achieved, and patient symptoms. BP = blood pressure; ECG = electrocardiography; HR = heart rate; MPHR = maximum predicted heart rate; MPI = myocardial perfusion imaging.

Metrics Rationale

The most critical of these metrics are the peak heart rate achieved, the METs achieved, whether the patient had symptoms, whether the patient was markedly fatigued (maximal stress), and the exercise time. These 5 metrics are essential. The other metrics provide a quality check. The reason these metrics are needed is that a patient could exercise less than 2 min and, because of severe deconditioning or obesity, achieve greater than 85% of the maximum predicted heart rate. The imaging would result in a false-negative result in this situation because less than 2 min of exercise are not sufficient to provoke maximal coronary artery dilation. The METs achieved and the heart rate are also important metrics, considered together, because an athlete could exercise for 6 min and achieve 5 METs, but because of conditioning, the patient’s heart rate may be significantly less than 85% of the maximum predicted value, and thus the coronary arteries may not be maximally dilated. Similarly, a patient could walk less than 2 min, exert less than 5 METs, and have crushing chest pain but still not have maximal coronary artery dilation. The concern with this scenario is that the chest pain could indicate coronary artery disease, but because the patient did not exercise long enough, the image findings may not be abnormal.

Several of the other metrics are germane to improving quality, the first being whether the patient was converted to a pharmacologic stress test if the 3 conditions were not met. If the 3 conditions are not met, there is an increased likelihood of false-negative results, meaning that patients are told they are disease-free when, in fact, they may have blockages in their coronary arteries increasing the likelihood of future myocardial infarction. Relatedly, another important quality metric is whether the scan results were normal or abnormal. If the laboratory truly wants to improve quality, it should also compare the imaging results with a gold standard such as cardiac catheterization (17). Comparison to a gold standard, or correlation, is a measure of the number of false-positives, false-negatives, true-positives, and true-negatives or, in other words, the accuracy of the test.

Metrics Goals

There are 2 goals associated with the collection of data from these metrics. First, a laboratory can determine the level of accuracy associated with myocardial perfusion imaging. As mentioned previously, 20%–50% of patients undergoing advanced diagnostic imaging do not receive results or information improving outcomes. Only through accurate results can we hope to improve patient outcomes. One way to improve the accuracy of a test is through proper performance. Thus, adherence to evidence-based procedure guidelines is a method for enhancing performance. The second goal of these metrics is to establish the degree of laboratory adherence to the clinical guidelines.

CONCLUSION

The Institute of Medicine’s definition of quality emphasizes patient outcomes through the application of evidence-based knowledge. There are several evidence-based imaging guidelines for the performance of stress myocardial perfusion imaging. These guidelines provide concise instructions on how to perform the test to obtain the highest level of accuracy. However, a laboratory cannot just assume tests are being performed correctly, nor can it assume tests comply with the guidelines. The only way to ensure these things, and thereby improve quality, is through measurement.

This paper provided a rationale for measuring the quality of cardiac exercise stress testing associated with myocardial perfusion imaging. At issue is the performance of maximal exercise to achieve accurate imaging results. Three conditions must be met to substantiate a maximal exercise test. The patient must exercise to a level of 5 METs or approximately 6 min on the treadmill. The patient’s heart rate must reach higher than 85% of the maximum predicted heart rate, and the patient must be symptomatic. These 3 conditions have been suggested, along with several other exercise attributes, as practical metrics to ascertain quality. From the measurement of these metrics, adherence to evidence-based guidelines and the accuracy of the cardiac stress test for myocardial perfusion imaging can be demonstrated. Affirming the words of H. James Harrington, measurement of exercise stress testing adequacy furthers understanding. Understanding the current performance of stress testing can assist a laboratory in controlling performance, and by controlling performance, a laboratory can facilitate improvement.

DISCLOSURE

Mary Beth Farrell is an employee of the Intersocietal Accreditation Commission. No other potential conflict of interest relevant to this article was reported.

Footnotes

  • Published online Apr. 10, 2020.

  • CE credit: For CE credit, you can access the test for this article, as well as additional JNMT CE tests, online at https://www.snmmilearningcenter.org. Complete the test online no later than June 2023. Your online test will be scored immediately. You may make 3 attempts to pass the test and must answer 80% of the questions correctly to receive 1.0 CEH (Continuing Education Hour) credit. SNMMI members will have their CEH credit added to their VOICE transcript automatically; nonmembers will be able to print out a CE certificate upon successfully completing the test. The online test is free to SNMMI members; nonmembers must pay $15.00 by credit card when logging onto the website to take the test.

REFERENCES

  1. 1.↵
    Institute of Medicine (IOM). Crossing the Quality Chasm: A New Health System for the 21st Century. Washington, DC: National Academy Press; 2001.
    Google Scholar
  2. 2.↵
    Definitions: emergencies. World Health Organization website. https://www.who.int/hac/about/definitions/en/. Accessed April 14, 2020.
    Google Scholar
  3. 3.↵
    1. Masic I,
    2. Miokovic M,
    3. Muhamedagic B
    . Evidence based medicine: new approaches and challenges. Acta Inform Med. 2008;16:219–225.
    OpenUrlCrossRefPubMedGoogle Scholar
  4. 4.↵
    1. Grimshaw JM,
    2. Russell IT
    . Effect of clinical guidelines on medical practice: a systematic review of rigorous evaluations. Lancet. 1993;342:1317–1322.
    OpenUrlCrossRefPubMedGoogle Scholar
  5. 5.↵
    1. Graham ID,
    2. Harrison MB
    . Evaluation and adaptation of clinical practice guidelines. Evid Based Nurs. 2005;8:68–72.
    OpenUrlFREE Full TextGoogle Scholar
  6. 6.↵
    1. Prusak L
    . What can’t be measured. Harvard Business Review website. https://hbr.org/2010/10/what-cant-be-measured. Published October 7, 2010. Accessed April 14, 2020.
    Google Scholar
  7. 7.↵
    1. Hutt M,
    2. Speh T
    . Business Marketing Management. Mason, OH: South-Western Cengage Learning; 2009.
    Google Scholar
  8. 8.↵
    1. Ogrinc GS,
    2. Headrick LA,
    3. Moore SM,
    4. Barton AJ,
    5. Dolansky MA,
    6. Madigosky WS
    . Fundamentals of Health Care Improvement: A Guide to Improving your Patients’ Care. 2nd ed. Oakbrook Terrace, IL: Joint Commission Resources; 2012.
    Google Scholar
  9. 9.↵
    1. Farrell MB,
    2. Abreu SH
    . A practical guide to quality improvement in nuclear medicine. J Nucl Med Technol. 2012;40:211–219.
    OpenUrlAbstract/FREE Full TextGoogle Scholar
  10. 10.↵
    2012 national healthcare quality report. U.S. Department of Health and Human Services website. https://archive.ahrq.gov/research/findings/nhqrdr/nhqr12/index.html. Last reviewed June 2013. Accessed April 14, 2020.
    Google Scholar
  11. 11.↵
    1. Hendee WR,
    2. Becker GJ,
    3. Borgstede JP,
    4. et al
    . Addressing overutilization in medical imaging. Radiology. 2010;257:240–245.
    OpenUrlCrossRefPubMedGoogle Scholar
  12. 12.↵
    1. Dilsizian V,
    2. Bacharach SL,
    3. Beanlands RS,
    4. et al
    . ASNC imaging guidelines/SNMMI procedure standard for positron emission tomography (PET) nuclear cardiology procedures. J Nucl Cardiol. 2016;23:1187–1226.
    OpenUrlGoogle Scholar
  13. 13.↵
    1. Shah NR,
    2. Ahmed S,
    3. Winchester D,
    4. et al
    . Facility-level variation in stress test utilization in veterans with ischemic heart disease. JACC Cardiovasc Imaging. 2019;12:1292–1293.
    OpenUrlFREE Full TextGoogle Scholar
  14. 14.↵
    1. Pagnanelli RA,
    2. Camposano H
    . Pharmacologic stress testing with myocardial perfusion imaging. J Nucl Med Technol. 2017;45:249–252.
    OpenUrlAbstract/FREE Full TextGoogle Scholar
  15. 15.↵
    1. Henzlova M,
    2. Duvall L,
    3. Einstein A,
    4. Travin M,
    5. Verberne H
    . ASNC imaging guidelines for SPECT nuclear cardiology procedures: stress, protocols, and tracers. J Nucl Cardiol. 2016;23:606–639.
    OpenUrlGoogle Scholar
  16. 16.↵
    1. Sharif S,
    2. Always S
    . The diagnostic value of exercise stress testing for cardiovascular disease is more than just ST segment changes: a review. J Integr Cardiol. 2016;2:341–355.
    Google Scholar
  17. 17.↵
    1. Koller D
    . Assessing diagnostic performance in nuclear cardiology. J Nucl Cardiol. 2002;9:114–123.
    OpenUrlCrossRefPubMedGoogle Scholar
  • Received for publication March 3, 2020.
  • Accepted for publication March 30, 2020.
PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine Technology: 48 (2)
Journal of Nuclear Medicine Technology
Vol. 48, Issue 2
June 1, 2020
  • Table of Contents
  • About the Cover
  • Index by author
Print
Download PDF
Article Alerts
Email Article
Citation Tools
Share
The Importance of Measurement for Quality Improvement: Submaximal Cardiac Stress Testing
Mary Beth Farrell
Journal of Nuclear Medicine Technology Jun 2020, 48 (2) 122-125; DOI: 10.2967/jnmt.120.244525
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
Bookmark this article

Jump to section

  • Article
    • Abstract
    • IMPORTANCE OF MEASURING QUALITY
    • QUALITY IN ADVANCED DIAGNOSTIC IMAGING
    • SUBMAXIMAL STRESS TESTING AND EVIDENCE-BASED GUIDELINES
    • SUBMAXIMAL STRESS QUALITY IMPROVEMENT
    • CONCLUSION
    • DISCLOSURE
    • Footnotes
    • REFERENCES
  • Figures & Data
  • Info & Metrics
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • COVID-19 and Its Impact on Nuclear Medicine
  • Google Scholar

More in this TOC Section

  • Illuminating the Hidden: Standardizing Cardiac MIBG Imaging for Sympathetic Dysfunction
  • PET/CT Case Series: Unmasking the Mystery of Cardiac Sarcoidosis
  • Delivery Methods of Radiopharmaceuticals: Exploring Global Strategies to Minimize Occupational Radiation Exposure
Show more Continuing Education

Similar Articles

Keywords

  • exercise stress testing
  • submaximal stress
  • quality improvement
  • measurement
  • guideline adherence
SNMMI

© 2025 SNMMI

Powered by HighWire
Alerts for this Article
Sign In to Email Alerts with your Email Address
Email this Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine Technology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
The Importance of Measurement for Quality Improvement: Submaximal Cardiac Stress Testing
(Your Name) has sent you a message from Journal of Nuclear Medicine Technology
(Your Name) thought you would like to see the Journal of Nuclear Medicine Technology web site.
Citation Tools
The Importance of Measurement for Quality Improvement: Submaximal Cardiac Stress Testing
Mary Beth Farrell
Journal of Nuclear Medicine Technology Jun 2020, 48 (2) 122-125; DOI: 10.2967/jnmt.120.244525

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero

We use cookies on this site to enhance your user experience

By clicking any link on this page you are giving your consent for us to set cookies.