Skip to main content

Main menu

  • Home
  • Content
    • Current
      • JNMT Supplement
    • Ahead of print
    • Past Issues
    • Continuing Education
    • JNMT Podcast
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Rates
    • Journal Claims
    • Institutional and Non-member
  • Authors
    • Submit to JNMT
    • Information for Authors
    • Assignment of Copyright
    • AQARA Requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
    • Corporate & Special Sales
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNMT
    • JNM
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine Technology
  • SNMMI
    • JNMT
    • JNM
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine Technology

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • Continuing Education
    • JNMT Podcast
    • SNMMI Annual Meeting Abstracts
  • Subscriptions
    • Subscribers
    • Rates
    • Journal Claims
    • Institutional and Non-member
  • Authors
    • Submit to JNMT
    • Information for Authors
    • Assignment of Copyright
    • AQARA Requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
    • Corporate & Special Sales
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • Watch or Listen to JNMT Podcast
  • Visit SNMMI on Facebook
  • Join SNMMI on LinkedIn
  • Follow SNMMI on Twitter
  • Subscribe to JNMT RSS feeds
Review ArticleTeaching Case Studies

The Impact of High-Dose Vitamin C on Blood Glucose Testing in 18F-FDG PET Imaging

Rebekah L. Bahr and Don C. Wilson
Journal of Nuclear Medicine Technology March 2015, 43 (1) 70-71; DOI: https://doi.org/10.2967/jnmt.114.140335
Rebekah L. Bahr
1Functional Imaging Program, BC Cancer Agency, Vancouver, British Columbia, Canada; and
RTNM
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Don C. Wilson
2BC Cancer Agency, Vancouver, British Columbia, Canada
FRCPC
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Info & Metrics
  • PDF
Loading

Abstract

Complementary and alternative therapies in addition to standard oncology protocols are commonly sought by cancer patients; however, few patients disclose their complementary treatments to their cancer care team. A lack of communication may result in unforeseen side effects and the potential for some alternative therapies to interfere with or inhibit conventional treatment. High-dose vitamin C therapy, in particular, may lead to an inability to measure a patient’s blood glucose level before 18F-FDG injection for PET/CT scanning. We report a case of a 52-y-old woman referred for 18F-FDG PET/CT to evaluate the extent of recurrent colorectal cancer. The PET/CT scan immediately followed a single intravenous dose of 25 g of ascorbic acid from her naturopath. A glucometer that applies the glucose oxidase method for measuring fasting blood glucose was used, for which high doses of vitamin C are listed as a contraindication. The high concentration of ascorbic acid in the patient’s blood sample interfered with the chemical reaction on the glucose strip, and therefore no blood glucose measurement could be attained. With more patients receiving alternative and complementary cancer therapies, it is important to know what the implications of orthomolecular therapy might be on routine blood glucose testing for 18F-FDG PET scans. 18F-FDG is in direct competition with glucose; therefore, elevated blood glucose levels will cause a decrease in 18F-FDG absorption and may lead to a false-negative scan.

  • vitamin C
  • ascorbic acid
  • blood glucose
  • PET

Alternative therapies combined with standard oncology protocols are commonly sought by cancer patients; however, few patients disclose their complementary treatments to their care team. A lack of communication may result in unforeseen side effects and can potentially interfere with conventional treatment. Intravenous high-dose vitamin C (ascorbic acid) therapy, in particular, may lead to an inability to measure a patient’s blood glucose level before 18F-FDG injection for PET/CT scanning.

CASE STUDY

A 52-y-old woman was referred for an 18F-FDG PET/CT scan to determine the extent of recurrent colorectal carcinoma. Fasting blood glucose level was measured before 18F-FDG injection by the drawing of a venous blood sample from an intravenous catheter. As per manufacturer guidelines, a drop of blood was placed on the glucose test strip (SureStep Pro; Lifescan). However, the drop of blood did not produce the anticipated reaction in which a blue color appears on the strip. The procedure was repeated with a new sample of blood and a new strip and was also unsuccessful.

Several blood samples were then obtained both from the patient’s intravenous line and from capillary samples from finger pokes, none of which reacted with any glucose strip. Six separate glucose strips were used from 3 different containers stored in various locations and 2 different lot numbers of strips.

On further questioning, it was found that 2 h before her PET/CT appointment, the patient had undergone an intravenous infusion of 25,000 mg of vitamin C. The package insert from the SureStep Pro glucometer test strips informs that vitamin C is an interfering substance but has no significant effect on blood glucose readings for physiologic vitamin C concentrations of up to 0.2 mmol/L (1). No other interfering substances were identified for this patient. No alternate means for testing blood glucose were accessible, but the patient was not diabetic and had followed a proper fasting protocol; therefore, 18F-FDG was administered and the PET/CT scan was performed. On image review, the scan results and 18F-FDG biodistribution did not seem to be compromised despite the vitamin C infusion and inability to measure the patient’s blood glucose level.

DISCUSSION

To measure blood glucose level using the Surestep Flexx Bedside Glucometer (Lifescan), a drop of blood is placed on the glucose strip and the blood reacts with glucose oxidase, triggering oxidation of glucose in the blood sample. Gluconic acid and hydrogen peroxidase are produced as a result of this reaction. Peroxidase on the test strip then causes the hydrogen peroxide to react with dyes to produce a blue color in the presence of oxygen. The glucometer is calibrated to interpret the patient’s blood glucose level, which is proportional to the intensity of blue produced on the sample glucose strip.

Inaccurate readings of blood glucose occur when high plasma concentrations of vitamin C interfere with chromagen oxygenation on the blood glucose strip, and no blue color appears (2). Typical doses of vitamin C would not cause interference during blood glucose testing, but large doses of intravenously administered ascorbic acid (50–100 mg) bypass absorptive mechanisms, producing high plasma concentrations of about 14,000 μmol/L (3).

A pioneer of megavitamin therapy and Nobel Prize winner, Linus Pauling advocated vitamin C as a prooxidant because it generates hydrogen peroxide (H2O2) in extracellular spaces. Hydrogen peroxide present in blood is toxic to cancer cells but not normal cells (4); thus, patients believe it will destroy cancer cells and free radicals such as those produced in the presence of ionizing radiation.

CONCLUSION

The inability to measure this patient’s blood glucose level with the glucometer test strip was most likely caused by interference from a high dose of vitamin C infused just before her PET/CT appointment. Having an accurate glucose reading before 18F-FDG injection is extremely important to ensure accurate 18F-FDG PET/CT scanning results. Technologists should understand the mechanics of the glucometer in use and know the limitations of glucose testing. Patients should be encouraged to disclose any alternative treatments to their care team.

DISCLOSURE

No potential conflict of interest relevant to this article was reported.

Footnotes

  • Published online Aug. 7, 2014.

REFERENCES

  1. 1.↵
    SureStep Pro Test Strips [package insert]. Milipitas, CA: Lifescan; 2003.
  2. 2.↵
    1. Tang Z,
    2. Du X,
    3. Louie R,
    4. Kost G
    . Effects of drugs on glucose measurements with handheld glucose meters and a portable glucose analyzer. Am J Clin Pathol. 2000;113:75–86.
    OpenUrlAbstract/FREE Full Text
  3. 3.↵
    1. Padayatty SJ,
    2. Riordan H,
    3. Hewitt S,
    4. Katz A,
    5. Hoffer L,
    6. Levine M
    . Intravenously administered vitamin C as cancer therapy: three cases. CMAJ. 2006;174:937–942.
    OpenUrlAbstract/FREE Full Text
  4. 4.↵
    1. Chen Q,
    2. Espey M,
    3. Krishna M,
    4. et al
    . Pharmacologic ascorbic acid concentrations selectively kill cancer cells: action as a pro-drug to deliver hydrogen peroxide to tissues. Proc Natl Acad Sci USA. 2005;102:13604–13609.
    OpenUrlAbstract/FREE Full Text
  • Received for publication March 14, 2014.
  • Accepted for publication April 30, 2014.
PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine Technology: 43 (1)
Journal of Nuclear Medicine Technology
Vol. 43, Issue 1
March 1, 2015
  • Table of Contents
  • About the Cover
  • Index by author
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine Technology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
The Impact of High-Dose Vitamin C on Blood Glucose Testing in 18F-FDG PET Imaging
(Your Name) has sent you a message from Journal of Nuclear Medicine Technology
(Your Name) thought you would like to see the Journal of Nuclear Medicine Technology web site.
Citation Tools
The Impact of High-Dose Vitamin C on Blood Glucose Testing in 18F-FDG PET Imaging
Rebekah L. Bahr, Don C. Wilson
Journal of Nuclear Medicine Technology Mar 2015, 43 (1) 70-71; DOI: 10.2967/jnmt.114.140335

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
The Impact of High-Dose Vitamin C on Blood Glucose Testing in 18F-FDG PET Imaging
Rebekah L. Bahr, Don C. Wilson
Journal of Nuclear Medicine Technology Mar 2015, 43 (1) 70-71; DOI: 10.2967/jnmt.114.140335
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
    • Abstract
    • CASE STUDY
    • DISCUSSION
    • CONCLUSION
    • DISCLOSURE
    • Footnotes
    • REFERENCES
  • Info & Metrics
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

  • High-Sensitivity Troponin Elevation in a Young Woman with Typical Chest Pain: The Heart of Matter
  • Prominent Right Ventricular Tracer Uptake: A Harbinger of Multivessel Coronary Artery Disease
  • SPECT/CT for Discrimination Between Active and Inactive Os Trigonum in Posterior Ankle Syndrome
Show more Teaching Case Studies

Similar Articles

Keywords

  • vitamin C
  • ascorbic acid
  • Blood glucose
  • PET
SNMMI

© 2025 SNMMI

Powered by HighWire